Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
Sensors · 22.06.2023 · 23 (13) · 5832
DOI: 10.3390/s23135832 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 22.06.2023. Verfasst von Raynier Montoro-Bombú und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Por…. Hauptthemen laut MEDLINE: Thigh, Muscle Strength. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal.
ORCID-Profile: Raynier Montoro-Bombú, Beatriz Branquinho Gomes, Amândio Santos, Luis Rama
Zitieren
APA
Montoro-Bombú, R., Gomes, B. B., Santos, A., & Rama, L. (2023). Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test. Sensors, 23(13), 5832. https://doi.org/10.3390/s23135832
Vancouver
Montoro-Bombú R, Gomes BB, Santos A, Rama L. Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test. Sensors. 2023;23(13):5832. doi:10.3390/s23135832
BibTeX
@article{MontoroBomb2023,
author = {Montoro-Bombú, Raynier and Gomes, Beatriz Branquinho and Santos, Amândio and Rama, Luis},
title = {Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test},
journal = {Sensors},
year = {2023},
volume = {23},
number = {13},
pages = {5832},
doi = {10.3390/s23135832}
}
EUVIMED