Proof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology
Sensors · 20.06.2023 · 23 (12) · 5769
DOI: 10.3390/s23125769 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 20.06.2023. Verfasst von Michael Callihan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Capstone College of Nursing, The University of Alabama, Tuscaloosa, AL 35401, USA. Hauptthemen laut MEDLINE: Moving and Lifting Patients, Occupational Diseases, Musculoskeletal Diseases, Wearable Electronic Devices. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Healthcare workers make up one of the occupations in the United States that experience the most musculoskeletal injuries. These injuries are often related to the movement and repositioning of patients. Despite previous injury prevention attempts, injury rates remain at an unsustainable level. The purpose of this proof-of-concept study is to provide preliminary testing of the impact of a lifting intervention on common biomechanical risk factors for injury during high-risk patient movements.; Methods: A before-and-after (quasi-experimental) design was utilized to compare biomechanical risk factors before and after a lifting intervention. Kinematic data were collected using the Xsens motion capture system, while muscle activations were collected with the Delsys Trigno EMG system.
Results
Improvements were noted in the lever arm distance, trunk velocity, and muscle activations during the movements following the intervention; Conclusions: The contextual lifting intervention shows a positive impact on the biomechanical risk factors for musculoskeletal injury among healthcare workers without increasing the biomechanical risk. A larger, prospective study is needed to determine the intervention’s ability to reduce injuries among healthcare workers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Capstone College of Nursing, The University of Alabama, Tuscaloosa, AL 35401, USA.
ORCID-Profile: Michael Callihan
Zitieren
APA
Callihan, M., Somers, B., Dinesh, D., Aldred, L., Clamp, K., Treglown, A., Custred, C., Porteous, K., & Szukala, E. (2023). Proof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology. Sensors, 23(12), 5769. https://doi.org/10.3390/s23125769
Vancouver
Callihan M, Somers B, Dinesh D, Aldred L, Clamp K, Treglown A, et al. Proof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology. Sensors. 2023;23(12):5769. doi:10.3390/s23125769
BibTeX
@article{Callihan2023,
author = {Callihan, Michael and Somers, Brylan and Dinesh, Dhruv and Aldred, Lauren and Clamp, Kaitlyn and Treglown, Alyssa and Custred, Cole and Porteous, Kathryn and Szukala, Emily},
title = {Proof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology},
journal = {Sensors},
year = {2023},
volume = {23},
number = {12},
pages = {5769},
doi = {10.3390/s23125769}
}
EUVIMED