EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Glassy Carbon Electrode Modified with CB/TiO2 Layer for Sensitive Determination of Sumatriptan by Means of Voltammetry and Flow Injection Analysis

Joanna Smajdor iD, Beata Paczosa-Bator iD, Małgorzata Grabarczyk iD, Robert Piech iD

Sensors · 2023

DOI: 10.3390/s23125397 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Joanna Smajdor und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Al. Mickiew…. Hauptthemen laut MEDLINE: Carbon, Sumatriptan. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AGH University of Science and Technology, Excellence initiative-research university.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sumatriptan is an organic chemical compound from the tryptamine group. It is used as a medicine for migraine attacks and in the treatment of cluster headaches. In this work, a new voltammetric method is proposed for highly sensitive SUM determination, using glassy carbon electrodes modified with carbon black and titanium dioxide suspension. The novelty of the presented work is the usage of the mixture of carbon black and TiO2 as glassy carbon electrode modifier for the first time for SUM determination. The mentioned sensor was characterized by great repeatability and sensitivity of measurements, which resulted in the obtention of a wide range of linearity and a low detection limit. The electrochemical properties of the CB-TiO2/GC sensor was characterized using the LSV and EIS method. The effect of different factors on the SUM peak, such as supporting electrolyte type, preconcentration time and potential, or influence of interferents, were tested using the square wave voltammetry technique. The linear voltammetric response for the analyte was obtained in the concentration range of 5 nmol L−1 to 150 μmol L−1 with a detection limit of 2.9 nmol L−1 for a preconcentration time of 150 s in the 0.1 mol L−1 phosphate buffer pH 6.0. The proposed method was successfully applied for highly sensitive sumatriptan determination in complex matrices, such as tablets, urine, and plasma, with a good recovery parameter (94–105%). The presented CB-TiO2/GC electrode is characterized by great stability, it was used for 6 weeks without significant changes in the SUM peak current. Amperometric and voltammetric measurements of SUM under the flow injection conditions were also performed to indicate the possibility of its fast and accurate determination with a time of single analysis of approx. 30 s.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarbonSumatriptanFlow Injection AnalysisSootElectrodesPhosphatesElectrochemical TechniquesTitanium

Stichwörter der Autor:innen

TiO2carbon blackflow injection analysissumatriptanvoltammetry

Substanzen

CarbonSumatriptanSootPhosphatestitanium dioxideTitaniumsodium polymetaphosphate

Autor:innen und Institutionen

  • Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Al. Mickiewicza, 30-059 Krakow, Poland.
  • Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland.

ORCID-Profile: Joanna Smajdor, Beata Paczosa-Bator, Małgorzata Grabarczyk, Robert Piech

Förderung

  • AGH University of Science and Technology
  • Excellence initiative-research university

Zitieren

APA

Smajdor, J., Paczosa-Bator, B., Grabarczyk, M., & Piech, R. (2023). Glassy Carbon Electrode Modified with CB/TiO2 Layer for Sensitive Determination of Sumatriptan by Means of Voltammetry and Flow Injection Analysis. Sensors. https://doi.org/10.3390/s23125397

Vancouver

Smajdor J, Paczosa-Bator B, Grabarczyk M, Piech R. Glassy Carbon Electrode Modified with CB/TiO2 Layer for Sensitive Determination of Sumatriptan by Means of Voltammetry and Flow Injection Analysis. Sensors. 2023. doi:10.3390/s23125397

BibTeX
@article{Smajdor2023,
  author = {Smajdor, Joanna and Paczosa-Bator, Beata and Grabarczyk, Małgorzata and Piech, Robert},
  title = {Glassy Carbon Electrode Modified with CB/TiO2 Layer for Sensitive Determination of Sumatriptan by Means of Voltammetry and Flow Injection Analysis},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23125397}
}
Kostenlos starten →