Evaluation of the Size of a Defect in Reinforcing Steel Using Magnetic Flux Leakage (MFL) Measurements

Jamal Yousaf iD, Regidestyoko Wasistha Harseno iD, Seong-Hoon Kee iD, Jurng-Jae Yee

Sensors · 2023

DOI: 10.3390/s23125374 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Jamal Yousaf und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of ICT Integrated Ocean Smart Cities Engineering, Dong-A University, Busan 49304, Republic of Korea. Hauptthemen laut MEDLINE: Magnets, Magnetics. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate 2D magnetic flux leakage (MFL) signals (Bx, By) in D19-size reinforcing steel with several defect conditions. The magnetic flux leakage data were collected from the defected and new specimens using an economically designed test setup incorporating permanent magnets. A two-dimensional finite element model was numerically simulated using COMSOL Multiphysics to validate the experimental tests. Based on the MFL signals (Bx, By), this study also intended to improve the ability to analyze defect features such as width, depth, and area. Both the numerical and experimental results indicated a high cross-correlation with a median coefficient of 0.920 and a mean coefficient of 0.860. Using signal information to evaluate defect width, the x-component (Bx) bandwidth was found to increase with increasing defect width and the y-component (By) amplitude rise with increasing depth. In this two-dimensional MFL signal study, both parameters of the two-dimensional defects (width and depth) affected each other and could not be evaluated individually. The defect area was estimated from the overall variation in the signal amplitude of the magnetic flux leakage signals with the x-component (Bx). The defect areas showed a higher regression coefficient (R2 = 0.9079) for the x-component (Bx) amplitude from the 3-axis sensor signal. It was determined that defect features are positively correlated with sensor signals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetsMagneticsMagnetic Phenomena

Stichwörter der Autor:innen

defect sizemagnetic flux leakagepermanent magnetsreinforcing steelssensors

Autor:innen und Institutionen

  • Department of ICT Integrated Ocean Smart Cities Engineering, Dong-A University, Busan 49304, Republic of Korea.
  • National Core Research Center for Disaster-Free and Safe Ocean Cities Construction, Dong-A University, Busan 49304, Republic of Korea.

ORCID-Profile: Jamal Yousaf, Regidestyoko Wasistha Harseno, Seong-Hoon Kee

Förderung

  • National Research Foundation of Korea
  • Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education

Zitieren

APA

Yousaf, J., Harseno, R. W., Kee, S. H., & Yee, J. J. (2023). Evaluation of the Size of a Defect in Reinforcing Steel Using Magnetic Flux Leakage (MFL) Measurements. Sensors. https://doi.org/10.3390/s23125374

Vancouver

Yousaf J, Harseno RW, Kee SH, Yee JJ. Evaluation of the Size of a Defect in Reinforcing Steel Using Magnetic Flux Leakage (MFL) Measurements. Sensors. 2023. doi:10.3390/s23125374

BibTeX
@article{Yousaf2023,
  author = {Yousaf, Jamal and Harseno, Regidestyoko Wasistha and Kee, Seong-Hoon and Yee, Jurng-Jae},
  title = {Evaluation of the Size of a Defect in Reinforcing Steel Using Magnetic Flux Leakage (MFL) Measurements},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23125374}
}