EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Precision Denavit–Hartenberg Parameter Calibration for Industrial Robots Using a Laser Tracker System and Intelligent Optimization Approaches

Mojtaba A Khanesar iD, Minrui Yan, Mohammed Isa iD, Samanta Piano, David T Branson

Sensors · 2023

DOI: 10.3390/s23125368 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Mojtaba A Khanesar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK. Hauptthemen laut MEDLINE: Robotics. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, UKRI Research England Development (RED) Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Precision object handling and manipulation require the accurate positioning of industrial robots. A common practice for performing end effector positioning is to read joint angles and use industrial robot forward kinematics (FKs). However, industrial robot FKs rely on the robot Denavit–Hartenberg (DH) parameter values, which include uncertainties. Sources of uncertainty associated with industrial robot FKs include mechanical wear, manufacturing and assembly tolerances, and robot calibration errors. It is therefore necessary to increase the accuracy of DH parameter values to reduce the impact of uncertainties on industrial robot FKs. In this paper, we use differential evolution, particle swarm optimization, an artificial bee colony, and a gravitational search algorithm to calibrate industrial robot DH parameters. A laser tracker system, Leica AT960-MR, is utilized to register accurate positional measurements. The nominal accuracy of this non-contact metrology equipment is less than 3 μm/m. Metaheuristic optimization approaches such as differential evolution, particle swarm optimization, an artificial bee colony and a gravitational search algorithm are used as optimization methods to perform the calibration using laser tracker position data. It is observed that, using the proposed approach with an artificial bee colony optimization algorithm, the accuracy of industrial robot FKs in terms of mean absolute errors of static and near-static motion over all three dimensions for the test data decreases from its measured value of 75.4 μm to 60.1 μm (a 20.3% improvement).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsCalibrationAlgorithmsMotionBiomechanical Phenomena

Stichwörter der Autor:innen

Denavit–Hartenberg parameter calibrationartificial intelligence for optimizationcollaborative robotsforward kinematic calibrationindustrial robotslaser tracker systempositional accuracy

Autor:innen und Institutionen

  • Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.

ORCID-Profile: Mojtaba A Khanesar, Mohammed Isa

Förderung

  • Engineering and Physical Sciences Research Council
  • UKRI Research England Development (RED) Fund

Zitieren

APA

Khanesar, M. A., Yan, M., Isa, M., Piano, S., & Branson, D. T. (2023). Precision Denavit–Hartenberg Parameter Calibration for Industrial Robots Using a Laser Tracker System and Intelligent Optimization Approaches. Sensors. https://doi.org/10.3390/s23125368

Vancouver

Khanesar MA, Yan M, Isa M, Piano S, Branson DT. Precision Denavit–Hartenberg Parameter Calibration for Industrial Robots Using a Laser Tracker System and Intelligent Optimization Approaches. Sensors. 2023. doi:10.3390/s23125368

BibTeX
@article{Khanesar2023,
  author = {Khanesar, Mojtaba A and Yan, Minrui and Isa, Mohammed and Piano, Samanta and Branson, David T},
  title = {Precision Denavit–Hartenberg Parameter Calibration for Industrial Robots Using a Laser Tracker System and Intelligent Optimization Approaches},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23125368}
}
Kostenlos starten →