A Quantitative Evaluation of the Performance of the Low-Cost AudioMoth Acoustic Recording Unit

Sam Lapp iD, Nickolus Stahlman, Justin Kitzes iD

Sensors · 01.06.2023 · 23 (11) · 5254

DOI: 10.3390/s23115254 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 01.06.2023. Verfasst von Sam Lapp und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological Sciences, University of Pittsburgh, 103 Clapp Hall, Fifth and Ruskin Avenues, Pittsburgh, PA 15260, USA. Hauptthemen laut MEDLINE: Noise, Acoustics. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, Gordon and Betty Moore Foundation, Department of Biological Sciences, University of Pittsburgh.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The AudioMoth is a popular autonomous recording unit (ARU) that is widely used to record vocalizing species in the field. Despite its growing use, there have been few quantitative tests on the performance of this recorder. Such information is needed to design effective field surveys and to appropriately analyze recordings made by this device. Here, we report the results of two tests designed to evaluate the performance characteristics of the AudioMoth recorder. First, we performed indoor and outdoor pink noise playback experiments to evaluate how different device settings, orientations, mounting conditions, and housing options affect frequency response patterns. We found little variation in acoustic performance between devices and relatively little effect of placing recorders in a plastic bag for weather protection. The AudioMoth has a mostly flat on-axis response with a boost above 3 kHz, with a generally omnidirectional response that suffers from attenuation behind the recorder, an effect that is accentuated when it is mounted on a tree. Second, we performed battery life tests under a variety of recording frequencies, gain settings, environmental temperatures, and battery types. We found that standard alkaline batteries last for an average of 189 h at room temperature using a 32 kHz sample rate, and that lithium batteries can last for twice as long at freezing temperatures compared to alkaline batteries. This information will aid researchers in both collecting and analyzing recordings generated by the AudioMoth recorder.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NoiseAcousticsTemperatureCold TemperatureHousing

Stichwörter der Autor:innen

ARUAudioMothacoustic monitoringautomated recording unit

Autor:innen und Institutionen

  • Department of Biological Sciences, University of Pittsburgh, 103 Clapp Hall, Fifth and Ruskin Avenues, Pittsburgh, PA 15260, USA.

ORCID-Profile: Sam Lapp, Justin Kitzes

Förderung

  • National Science Foundation
  • Gordon and Betty Moore Foundation
  • Department of Biological Sciences, University of Pittsburgh
  • Department of Biological Sciences at the University of Pittsburgh

Zitieren

APA

Lapp, S., Stahlman, N., & Kitzes, J. (2023). A Quantitative Evaluation of the Performance of the Low-Cost AudioMoth Acoustic Recording Unit. Sensors, 23(11), 5254. https://doi.org/10.3390/s23115254

Vancouver

Lapp S, Stahlman N, Kitzes J. A Quantitative Evaluation of the Performance of the Low-Cost AudioMoth Acoustic Recording Unit. Sensors. 2023;23(11):5254. doi:10.3390/s23115254

BibTeX
@article{Lapp2023,
  author = {Lapp, Sam and Stahlman, Nickolus and Kitzes, Justin},
  title = {A Quantitative Evaluation of the Performance of the Low-Cost AudioMoth Acoustic Recording Unit},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {11},
  pages = {5254},
  doi = {10.3390/s23115254}
}
Kostenlos starten →