EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ratiometric Sensing of Glyphosate in Water Using Dual Fluorescent Carbon Dots

Adryanne Clermont-Paquette, Diego-Andrés Mendoza, Amir Sadeghi, Alisa Piekny, Rafik Naccache iD

Sensors · 30.05.2023 · 23 (11) · 5200

DOI: 10.3390/s23115200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 30.05.2023. Verfasst von Adryanne Clermont-Paquette und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for NanoScience Research, Department of Chemistry and Biochemistry, Concordia University, Montreal, QC H4B 1R6, Canada. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, Natural Science and Engineering Research Council of Canada and Concordia University Research Chair Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glyphosate is a broad-spectrum pesticide used in crops and is found in many products used by industry and consumers. Unfortunately, glyphosate has been shown to have some toxicity toward many organisms found in our ecosystems and has been reported to have carcinogenic effects on humans. Hence, there is a need to develop novel nanosensors that are more sensitive and facile and permit rapid detection. Current optical-based assays are limited as they rely on changes in signal intensity, which can be affected by multiple factors in the sample. Herein, we report the development of a dual emissive carbon dot (CD) system that can be used to optically detect glyphosate pesticides in water at different pH levels. The fluorescent CDs emit blue and red fluorescence, which we exploit as a ratiometric self-referencing assay. We observe red fluorescence quenching with increasing concentrations of glyphosate in the solution, ascribed to the interaction of the glyphosate pesticide with the CD surface. The blue fluorescence remains unaffected and serves as a reference in this ratiometric approach. Using fluorescence quenching assays, a ratiometric response is observed in the ppm range with detection limits as low as 0.03 ppm. Our CDs can be used to detect other pesticides and contaminants in water, as cost-effective and simple environmental nanosensors.

Schlagwörter

Stichwörter der Autor:innen

carbon dotsglyphosateratiometric fluorescencesensing

Autor:innen und Institutionen

  • Center for NanoScience Research, Department of Chemistry and Biochemistry, Concordia University, Montreal, QC H4B 1R6, Canada.
  • Quebec Centre for Advanced Materials, Department of Chemistry and Biochemistry, Concordia University, Montreal, QC H4B 1R6, Canada.
  • Centre for Microscopy and Cellular Imaging, Department of Biology, Concordia University, Montreal, QC H4B 1R6, Canada.

ORCID-Profile: Rafik Naccache

Förderung

  • Natural Sciences and Engineering Research Council
  • Natural Science and Engineering Research Council of Canada and Concordia University Research Chair Program

Zitieren

APA

Clermont-Paquette, A., Mendoza, D. A., Sadeghi, A., Piekny, A., & Naccache, R. (2023). Ratiometric Sensing of Glyphosate in Water Using Dual Fluorescent Carbon Dots. Sensors, 23(11), 5200. https://doi.org/10.3390/s23115200

Vancouver

Clermont-Paquette A, Mendoza DA, Sadeghi A, Piekny A, Naccache R. Ratiometric Sensing of Glyphosate in Water Using Dual Fluorescent Carbon Dots. Sensors. 2023;23(11):5200. doi:10.3390/s23115200

BibTeX
@article{ClermontPaquette2023,
  author = {Clermont-Paquette, Adryanne and Mendoza, Diego-Andrés and Sadeghi, Amir and Piekny, Alisa and Naccache, Rafik},
  title = {Ratiometric Sensing of Glyphosate in Water Using Dual Fluorescent Carbon Dots},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {11},
  pages = {5200},
  doi = {10.3390/s23115200}
}
Kostenlos starten →