EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector

Hojik Kim iD, Junhyeok Kim, Jisung Hwang, Kilyoung Ko, Gyuseong Cho

Sensors · 09.05.2023 · 23 (10) · 4591

DOI: 10.3390/s23104591 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.05.2023. Verfasst von Hojik Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear and Quantun Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon 34341, Republi…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Estimating accurate radiation doses when a radioactive source’s location is unknown can protect workers from radiation exposure. Unfortunately, depending on a detector’s shape and directional response variations, conventional G(E) function can be prone to inaccurate dose estimations. Therefore, this study estimated accurate radiation doses regardless of source distributions, using the multiple G(E) function groups (i.e., pixel-grouping G(E) functions) within a position-sensitive detector (PSD), which records the response position and energy inside the detector. Investigations revealed that, compared with the conventional G(E) function when source distributions are unknown, this study’s proposed pixel-grouping G(E) functions improved dose estimation accuracy by more than 1.5 times. Furthermore, although the conventional G(E) function produced substantially larger errors in certain directions or energy ranges, the proposed pixel-grouping G(E) functions estimate doses with more uniform errors at all directions and energies. Therefore, the proposed method estimates the dose with high accuracy and provides reliable results regardless of the location and energy of the source.

Schlagwörter

Stichwörter der Autor:innen

G(E) functionambient dose equivalentcadmium zinc telluride (CZT)position sensitive detector (PSD)spectrum-to-dose conversion coefficient

Autor:innen und Institutionen

  • Department of Nuclear and Quantun Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon 34341, Republic of Korea.

ORCID-Profile: Hojik Kim

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Kim, H., Kim, J., Hwang, J., Ko, K., & Cho, G. (2023). Pixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector. Sensors, 23(10), 4591. https://doi.org/10.3390/s23104591

Vancouver

Kim H, Kim J, Hwang J, Ko K, Cho G. Pixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector. Sensors. 2023;23(10):4591. doi:10.3390/s23104591

BibTeX
@article{Kim2023,
  author = {Kim, Hojik and Kim, Junhyeok and Hwang, Jisung and Ko, Kilyoung and Cho, Gyuseong},
  title = {Pixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {10},
  pages = {4591},
  doi = {10.3390/s23104591}
}
Kostenlos starten →