Übersichtsarbeit in der Zeitschrift Sensors, online erschienen am 17.04.2023. Verfasst von Lev Dorosinskiy und 1 weiteren Autor:innen. Beteiligte Einrichtung: TUBITAK National Metrology Institute (TUBITAK UME), Dr. Zeki Acar Cad. No.1, Gebze 41470, Kocaeli, Turkey. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EMPIR program co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation program, EMPIR program cofinanced by the Participating States and from the European Union’s Horizon 2020 research and innovation program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magneto-optical indicator films (MOIFs) are a very useful tool for direct studies of the spatial distribution of magnetic fields and the magnetization processes in magnetic materials and industrial devices such as magnetic sensors, microelectronic components, micro-electromechanical systems (MEMS), and others. The ease of application and the possibility for direct quantitative measurements in combination with a straightforward calibration approach make them an indispensable tool for a wide spectrum of magnetic measurements. The basic sensor parameters of MOIFs, such as a high spatial resolution down to below 1 μm combined with a large spatial imaging range of up to several cm and a wide dynamic range from 10 μT to over 100 mT, also foster their application in various areas of scientific research and industry. The history of MOIF development totals approximately 30 years, and only recently have the underlying physics been completely described and detailed calibration approaches been developed. The present review first summarizes the history of MOIF development and applications and then presents the recent advances in MOIF measurement techniques, including the theoretical developments and traceable calibration methods. The latter make MOIFs a quantitative tool capable of measuring the complete vectorial value of a stray field. Furthermore, various scientific and industrial application areas of MOIFs are described in detail.

Schlagwörter

Stichwörter der Autor:innen

Faraday effectMOIFcalibrationlocal magnetic field measurementsmagnetic sensorsmagneto-opticsquantitative

Autor:innen und Institutionen

  • TUBITAK National Metrology Institute (TUBITAK UME), Dr. Zeki Acar Cad. No.1, Gebze 41470, Kocaeli, Turkey.
  • Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, D-38116 Braunschweig, Germany.

ORCID-Profile: Sibylle Sievers

Förderung

  • EMPIR program co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation program
  • EMPIR program cofinanced by the Participating States and from the European Union’s Horizon 2020 research and innovation program

Zitieren

APA

Dorosinskiy, L., & Sievers, S. (2023). Magneto-Optical Indicator Films: Fabrication, Principles of Operation, Calibration, and Applications. Sensors, 23(8), 4048. https://doi.org/10.3390/s23084048

Vancouver

Dorosinskiy L, Sievers S. Magneto-Optical Indicator Films: Fabrication, Principles of Operation, Calibration, and Applications. Sensors. 2023;23(8):4048. doi:10.3390/s23084048

BibTeX
@article{Dorosinskiy2023,
  author = {Dorosinskiy, Lev and Sievers, Sibylle},
  title = {Magneto-Optical Indicator Films: Fabrication, Principles of Operation, Calibration, and Applications},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {8},
  pages = {4048},
  doi = {10.3390/s23084048}
}
Kostenlos starten →