Automated Machine Learning Strategies for Multi-Parameter Optimisation of a Caesium-Based Portable Zero-Field Magnetometer
Sensors · 15.04.2023 · 23 (8) · 4007
DOI: 10.3390/s23084007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 15.04.2023. Verfasst von Rach Dawson und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Scottish Universities Physics Alliance SUPA, University of Strathclyde, Glasgow G4 0NG, UK. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UK Research and Innovation, UKRI.
Abstract (Originalsprache)
Machine learning (ML) is an effective tool to interrogate complex systems to find optimal parameters more efficiently than through manual methods. This efficiency is particularly important for systems with complex dynamics between multiple parameters and a subsequent high number of parameter configurations, where an exhaustive optimisation search would be impractical. Here we present a number of automated machine learning strategies utilised for optimisation of a single-beam caesium (Cs) spin exchange relaxation free (SERF) optically pumped magnetometer (OPM). The sensitivity of the OPM (T/Hz), is optimised through direct measurement of the noise floor, and indirectly through measurement of the on-resonance demodulated gradient (mV/nT) of the zero-field resonance. Both methods provide a viable strategy for the optimisation of sensitivity through effective control of the OPM’s operational parameters. Ultimately, this machine learning approach increased the optimal sensitivity from 500 fT/Hz to
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics, Scottish Universities Physics Alliance SUPA, University of Strathclyde, Glasgow G4 0NG, UK.
ORCID-Profile: Rach Dawson, Carolyn O'Dwyer, Edward Irwin, Marcin S Mrozowski, Dominic Hunter, Stuart Ingleby, Erling Riis, Paul F Griffin
Förderung
- UK Research and Innovation
- UKRI
Zitieren
APA
Dawson, R., O'Dwyer, C., Irwin, E., Mrozowski, M. S., Hunter, D., Ingleby, S., Riis, E., & Griffin, P. F. (2023). Automated Machine Learning Strategies for Multi-Parameter Optimisation of a Caesium-Based Portable Zero-Field Magnetometer. Sensors, 23(8), 4007. https://doi.org/10.3390/s23084007
Vancouver
Dawson R, O'Dwyer C, Irwin E, Mrozowski MS, Hunter D, Ingleby S, et al. Automated Machine Learning Strategies for Multi-Parameter Optimisation of a Caesium-Based Portable Zero-Field Magnetometer. Sensors. 2023;23(8):4007. doi:10.3390/s23084007
BibTeX
@article{Dawson2023,
author = {Dawson, Rach and O'Dwyer, Carolyn and Irwin, Edward and Mrozowski, Marcin S and Hunter, Dominic and Ingleby, Stuart and Riis, Erling and Griffin, Paul F},
title = {Automated Machine Learning Strategies for Multi-Parameter Optimisation of a Caesium-Based Portable Zero-Field Magnetometer},
journal = {Sensors},
year = {2023},
volume = {23},
number = {8},
pages = {4007},
doi = {10.3390/s23084007}
}