Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite Electrode
Sensors · 04.04.2023 · 23 (7) · 3727
DOI: 10.3390/s23073727 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.04.2023. Verfasst von Tatiana V Shishkanova und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, University of Chemistry and Technology, Technická 5, 166 28 Prague, Czech Republic. Hauptthemen laut MEDLINE: Graphite, Neuroblastoma. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Specific University research grant by Ministry of Education, Youth and Sports of the Czech Republic, Ministry of Education, Youth and Sports of the Czech Republic, UCT Prague, CZ.
Abstract (Originalsprache)
Vanillylmandelic acid (VMA) and homovanillic acid (HVA) are diagnostic markers of neuroblastoma. The purpose of this study was to understand the reason for the discrimination of structural analogues (VMA and HVA) onto a graphite electrode coated with an electrochemically oxidized urea derivative. Density functional theory calculations (DFT), FTIR spectroscopic measurements, and electrochemical impedance spectroscopic measurements were used in this work. Density functional theory calculations (DFT) were used to identify the most suitable binding sites of the urea derivative and to describe possible differences in its interaction with the studied analytes. The FTIR measurement indicated the enhancement and disappearance of NH vibrations on graphite and platinum surfaces, respectively, that could be connected to a different orientation and thus provide accessibility of the urea moiety for the discrimination of carboxylates. Additionally, the higher the basicity of the anion, the stronger the hydrogen-bonding interaction with –NH-groups of the urea moiety: VMA (pKb = 10.6, KAds = (5.18 ± 1.95) × 105) and HVA (pKb = 9.6, KAds = (4.78 ± 1.58) × 104). The differential pulse voltammetric method was applied to detect VMA and HVA as individual species and interferents. As individual analytes, both HVA and VMA can be detected at a concentration of 1.99 × 10−5 M (RSD ≤ 0.28, recovery 110–115%).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, University of Chemistry and Technology, Technická 5, 166 28 Prague, Czech Republic.
ORCID-Profile: Tatiana V Shishkanova
Förderung
- Specific University research grant by Ministry of Education, Youth and Sports of the Czech Republic
- Ministry of Education, Youth and Sports of the Czech Republic, UCT Prague, CZ
Zitieren
APA
Shishkanova, T. V., Králík, F., & Synytsya, A. (2023). Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite Electrode. Sensors, 23(7), 3727. https://doi.org/10.3390/s23073727
Vancouver
Shishkanova TV, Králík F, Synytsya A. Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite Electrode. Sensors. 2023;23(7):3727. doi:10.3390/s23073727
BibTeX
@article{Shishkanova2023,
author = {Shishkanova, Tatiana V and Králík, František and Synytsya, Alla},
title = {Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite Electrode},
journal = {Sensors},
year = {2023},
volume = {23},
number = {7},
pages = {3727},
doi = {10.3390/s23073727}
}
EUVIMED