Fachartikel in der Zeitschrift Sensors, online erschienen am 03.04.2023. Verfasst von Paolo Bonifati und 4 weiteren Autor:innen. Beteiligte Einrichtung: Research Center "E. Piaggio", Department of Information Engineering, University of Pisa, Largo Lucio Lazzarino 1, 56126 Pisa, Italy. Hauptthemen laut MEDLINE: Upper Extremity, Wearable Electronic Devices. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, Ministry of Education, Universities and Research, European Union’s Horizon 2020 Research and Innovation Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sensing solutions have emerged as a promising paradigm for monitoring human musculoskeletal state in an unobtrusive way. To increase the deployability of these systems, considerations related to cost reduction and enhanced form factor and wearability tend to discourage the number of sensors in use. In our previous work, we provided a theoretical solution to the problem of jointly reconstructing the entire muscular-kinematic state of the upper limb, when only a limited amount of optimally retrieved sensory data are available. However, the effective implementation of these methods in a physical, under-sensorized wearable has never been attempted before. In this work, we propose to bridge this gap by presenting an under-sensorized system based on inertial measurement units (IMUs) and surface electromyography (sEMG) electrodes for the reconstruction of the upper limb musculoskeletal state, focusing on the minimization of the sensors’ number. We found that, relying on two IMUs only and eight sEMG sensors, we can conjointly reconstruct all 17 degrees of freedom (five joints, twelve muscles) of the upper limb musculoskeletal state, yielding a median normalized RMS error of 8.5% on the non-measured joints and 2.5% on the non-measured muscles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Upper ExtremityWearable Electronic DevicesHumansBiomechanical PhenomenaMotion

Stichwörter der Autor:innen

IMUsSensor Fusionhuman multimodal motion trackingoptimal designsEMG sensorsupper limbwearable sensing

Autor:innen und Institutionen

  • Research Center "E. Piaggio", Department of Information Engineering, University of Pisa, Largo Lucio Lazzarino 1, 56126 Pisa, Italy.
  • Department of Control and Computer Engineering, Politecnico di Torino, 10129 Torino, Italy.

ORCID-Profile: Paolo Bonifati, Marco Baracca

Förderung

  • European Union
  • Ministry of Education, Universities and Research
  • European Union’s Horizon 2020 Research and Innovation Program
  • TIGHT: Tactile InteGration for Humans and arTificial systems

Zitieren

APA

Bonifati, P., Baracca, M., Menolotto, M., Averta, G., & Bianchi, M. (2023). A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion. Sensors, 23(7), 3716. https://doi.org/10.3390/s23073716

Vancouver

Bonifati P, Baracca M, Menolotto M, Averta G, Bianchi M. A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion. Sensors. 2023;23(7):3716. doi:10.3390/s23073716

BibTeX
@article{Bonifati2023,
  author = {Bonifati, Paolo and Baracca, Marco and Menolotto, Mariangela and Averta, Giuseppe and Bianchi, Matteo},
  title = {A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {7},
  pages = {3716},
  doi = {10.3390/s23073716}
}
Kostenlos starten →