EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Method for Stress Detection Using Empatica E4 Bracelet and Machine-Learning Techniques

Sara Campanella iD, Ayham Altaleb iD, Alberto Belli iD, Paola Pierleoni iD, Lorenzo Palma iD

Sensors · 29.03.2023 · 23 (7) · 3565

DOI: 10.3390/s23073565 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.03.2023. Verfasst von Sara Campanella und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Engineering (DII), Università Politecnica delle Marche, 60131 Ancona, Italy. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 102-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In response to challenging circumstances, the human body can experience marked levels of anxiety and distress. To prevent stress-related complications, timely identification of stress symptoms is crucial, necessitating the need for continuous stress monitoring. Wearable devices offer a means of real-time and ongoing data collection, facilitating personalized stress monitoring. Based on our protocol for data pre-processing, this study proposes to analyze signals obtained from the Empatica E4 bracelet using machine-learning algorithms (Random Forest, SVM, and Logistic Regression) to determine the efficacy of the abovementioned techniques in differentiating between stressful and non-stressful situations. Photoplethysmographic and electrodermal activity signals were collected from 29 subjects to extract 27 features which were then fed into three different machine-learning algorithms for binary classification. Using MATLAB after applying the chi-square test and Pearson’s correlation coefficient on WEKA for features’ importance ranking, the results demonstrated that the Random Forest model has the highest stability (accuracy of 76.5%) using all the features. Moreover, the Random Forest applying the chi-test for feature selection reached consistent results in terms of stress evaluation based on precision, recall, and F1-measure (71%, 60%, 65%, respectively).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesHumansMachine LearningAlgorithmsRandom ForestData Collection

Stichwörter der Autor:innen

Empatica E4IoTchi-square testmachine learningobjective stress measurementwearable sensors

Autor:innen und Institutionen

  • Department of Information Engineering (DII), Università Politecnica delle Marche, 60131 Ancona, Italy.

ORCID-Profile: Sara Campanella, Ayham Altaleb, Alberto Belli, Paola Pierleoni, Lorenzo Palma

Zitieren

APA

Campanella, S., Altaleb, A., Belli, A., Pierleoni, P., & Palma, L. (2023). A Method for Stress Detection Using Empatica E4 Bracelet and Machine-Learning Techniques. Sensors, 23(7), 3565. https://doi.org/10.3390/s23073565

Vancouver

Campanella S, Altaleb A, Belli A, Pierleoni P, Palma L. A Method for Stress Detection Using Empatica E4 Bracelet and Machine-Learning Techniques. Sensors. 2023;23(7):3565. doi:10.3390/s23073565

BibTeX
@article{Campanella2023,
  author = {Campanella, Sara and Altaleb, Ayham and Belli, Alberto and Pierleoni, Paola and Palma, Lorenzo},
  title = {A Method for Stress Detection Using Empatica E4 Bracelet and Machine-Learning Techniques},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {7},
  pages = {3565},
  doi = {10.3390/s23073565}
}
Kostenlos starten →