Remote Blood Pressure Estimation via the Spatiotemporal Mapping of Facial Videos
Sensors · 09.03.2023 · 23 (6) · 2963
DOI: 10.3390/s23062963 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 09.03.2023. Verfasst von Yuheng Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Automation, College of Electrical Engineering, Sichuan University, Chengdu 610065, China. Hauptthemen laut MEDLINE: Blood Pressure Determination, Face. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sichuan Science and Technology Program, Shanxi Provincial Natural Science Basic Research Program.
Abstract (Originalsprache)
Blood pressure (BP) monitoring is vital in daily healthcare, especially for cardiovascular diseases. However, BP values are mainly acquired through a contact-sensing method, which is inconvenient and unfriendly for BP monitoring. This paper proposes an efficient end-to-end network for estimating BP values from a facial video to achieve remote BP estimation in daily life. The network first derives a spatiotemporal map of a facial video. Then, it regresses the BP ranges with a designed blood pressure classifier and simultaneously calculates the specific value with a blood pressure calculator in each BP range based on the spatiotemporal map. In addition, an innovative oversampling training strategy was developed to handle the problem of unbalanced data distribution. Finally, we trained the proposed blood pressure estimation network on a private dataset, MPM-BP, and tested it on a popular public dataset, MMSE-HR. As a result, the proposed network achieved a mean absolute error (MAE) and root mean square error (RMSE) of 12.35 mmHg and 16.55 mmHg on systolic BP estimations, and those for diastolic BP were 9.54 mmHg and 12.22 mmHg, which were better than the values obtained in recent works. It can be concluded that the proposed method has excellent potential for camera-based BP monitoring in the indoor scenarios in the real world.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Automation, College of Electrical Engineering, Sichuan University, Chengdu 610065, China.
- Key Laboratory of Information and Automation Technology of Sichuan Province, Chengdu 610065, China.
- School of Computer Science, Northwest University, Xi'an 710069, China.
- School of Information Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
ORCID-Profile: Xiujuan Zheng
Förderung
- Sichuan Science and Technology Program
- Shanxi Provincial Natural Science Basic Research Program
Zitieren
APA
Chen, Y., Zhuang, J., Li, B., Zhang, Y., & Zheng, X. (2023). Remote Blood Pressure Estimation via the Spatiotemporal Mapping of Facial Videos. Sensors, 23(6), 2963. https://doi.org/10.3390/s23062963
Vancouver
Chen Y, Zhuang J, Li B, Zhang Y, Zheng X. Remote Blood Pressure Estimation via the Spatiotemporal Mapping of Facial Videos. Sensors. 2023;23(6):2963. doi:10.3390/s23062963
BibTeX
@article{Chen2023,
author = {Chen, Yuheng and Zhuang, Jialiang and Li, Bin and Zhang, Yun and Zheng, Xiujuan},
title = {Remote Blood Pressure Estimation via the Spatiotemporal Mapping of Facial Videos},
journal = {Sensors},
year = {2023},
volume = {23},
number = {6},
pages = {2963},
doi = {10.3390/s23062963}
}
EUVIMED