EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measurement Uncertainty in Clinical Validation Studies of Sensors

John Mark Ansermino iD, Guy Albert Dumont iD, Amy Sarah Ginsburg iD

Sensors · 07.03.2023 · 23 (6) · 2900

DOI: 10.3390/s23062900 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.03.2023. Verfasst von John Mark Ansermino und 2 weiteren Autor:innen. Beteiligte Einrichtung: British Columbia Children's Hospital Research Institute, The University of British Columbia, Vancouver, BC V6T 1Z6, Canada. Hauptthemen laut MEDLINE: Clinical Decision-Making. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate clinical sensors and devices are essential to support optimal medical decision-making, and accuracy can be demonstrated through the conduct of clinical validation studies using validated reference sensors and/or devices for comparison. Typically unmeasurable, the true reference value can be substituted with an accepted physiological measurement with an associated uncertainty. We describe a basic model of measurement uncertainty that specifies the factors that may degrade the accuracy of an observed measurement value from a sensor, and we detail validation study design strategies that may be used to quantify and minimize these uncertainties. In addition, we describe a model that extends the observed measurement uncertainty to the resultant clinical decision and the factors that may impact the uncertainty of this decision. Clinical validation studies should be designed to estimate and minimize uncertainty that is unrelated to the sensor accuracy. The contribution of measurement observation uncertainty to clinical decision-making should be minimized but also acknowledged and incorporated into the clinical decision-making process.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical Decision-MakingUncertaintyReference Values

Stichwörter der Autor:innen

accuracyagreementbiasclinical decision-makingdevice validationmeasurementprecisionreference devicesensorsuncertainty

Autor:innen und Institutionen

  • British Columbia Children's Hospital Research Institute, The University of British Columbia, Vancouver, BC V6T 1Z6, Canada.
  • Department of Electrical and Computer Engineering, British Columbia Children's Hospital Research Institute, The University of British Columbia, Vancouver, BC V6T 1Z8, Canada.
  • Clinical Trials Center, University of Washington, Seattle, WA 98105, USA.

ORCID-Profile: John Mark Ansermino, Guy Albert Dumont, Amy Sarah Ginsburg

Zitieren

APA

Ansermino, J. M., Dumont, G. A., & Ginsburg, A. S. (2023). Measurement Uncertainty in Clinical Validation Studies of Sensors. Sensors, 23(6), 2900. https://doi.org/10.3390/s23062900

Vancouver

Ansermino JM, Dumont GA, Ginsburg AS. Measurement Uncertainty in Clinical Validation Studies of Sensors. Sensors. 2023;23(6):2900. doi:10.3390/s23062900

BibTeX
@article{Ansermino2023,
  author = {Ansermino, John Mark and Dumont, Guy Albert and Ginsburg, Amy Sarah},
  title = {Measurement Uncertainty in Clinical Validation Studies of Sensors},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {6},
  pages = {2900},
  doi = {10.3390/s23062900}
}
Kostenlos starten →