EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Self-Excited Microcantilever with Higher Mode Using Band-Pass Filter

Yuji Hyodo iD, Hiroshi Yabuno iD

Sensors · 06.03.2023 · 23 (5) · 2849

DOI: 10.3390/s23052849 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 06.03.2023. Verfasst von Yuji Hyodo und 1 weiteren Autor:innen. Beteiligte Einrichtung: Degrees Programs in Systems and Information Engineering, Graduate School of Science and Technology, University of Tsukuba, Tsukuba 305-8573, Ibaraki,…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Culture, Sports, Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microresonators have a variety of scientific and industrial applications. The measurement methods based on the natural frequency shift of a resonator have been studied for a wide range of applications, including the detection of the microscopic mass and measurements of viscosity and stiffness. A higher natural frequency of the resonator realizes an increase in the sensitivity and a higher-frequency response of the sensors. In the present study, by utilizing the resonance of a higher mode, we propose a method to produce the self-excited oscillation with a higher natural frequency without downsizing the resonator. We establish the feedback control signal for the self-excited oscillation using the band-pass filter so that the signal consists of only the frequency corresponding to the desired excitation mode. It results that careful position setting of the sensor for constructing a feedback signal, which is needed in the method based on the mode shape, is not necessary. By the theoretical analysis of the equations governing the dynamics of the resonator coupled with the band-pass filter, it is clarified that the self-excited oscillation is produced with the second mode. Furthermore, the validity of the proposed method is experimentally confirmed by an apparatus using a microcantilever.

Schlagwörter

Stichwörter der Autor:innen

MEMShigher modemicrocantileverself-excited oscillation

Autor:innen und Institutionen

  • Degrees Programs in Systems and Information Engineering, Graduate School of Science and Technology, University of Tsukuba, Tsukuba 305-8573, Ibaraki, Japan.

ORCID-Profile: Yuji Hyodo, Hiroshi Yabuno

Förderung

  • Ministry of Education, Culture, Sports, Science and Technology

Zitieren

APA

Hyodo, Y., & Yabuno, H. (2023). Self-Excited Microcantilever with Higher Mode Using Band-Pass Filter. Sensors, 23(5), 2849. https://doi.org/10.3390/s23052849

Vancouver

Hyodo Y, Yabuno H. Self-Excited Microcantilever with Higher Mode Using Band-Pass Filter. Sensors. 2023;23(5):2849. doi:10.3390/s23052849

BibTeX
@article{Hyodo2023,
  author = {Hyodo, Yuji and Yabuno, Hiroshi},
  title = {Self-Excited Microcantilever with Higher Mode Using Band-Pass Filter},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {5},
  pages = {2849},
  doi = {10.3390/s23052849}
}