Fachartikel in der Zeitschrift Sensors, online erschienen am 04.03.2023. Verfasst von Ivan Vajs und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, University of Belgrade, 11120 Belgrade, Serbia. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Science and Technological Development of the Republic of Serbia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Public air quality monitoring relies on expensive monitoring stations which are highly reliable and accurate but require significant maintenance and cannot be used to form a high spatial resolution measurement grid. Recent technological advances have enabled air quality monitoring that uses low-cost sensors. Being inexpensive and mobile, with wireless transfer support, such devices represent a very promising solution for hybrid sensor networks comprising public monitoring stations supported by many low-cost devices for complementary measurements. However, low-cost sensors can be influenced by weather and degradation, and considering that a spatially dense network would include them in large numbers, logistically adept solutions for low-cost device calibration are essential. In this paper, we investigate the possibility of a data-driven machine learning calibration propagation in a hybrid sensor network consisting of One public monitoring station and ten low-cost devices equipped with NO2, PM10, relative humidity, and temperature sensors. Our proposed solution relies on calibration propagation through a network of low-cost devices where a calibrated low-cost device is used to calibrate an uncalibrated device. This method has shown an improvement of up to 0.35/0.14 for the Pearson correlation coefficient and a reduction of 6.82 µg/m3/20.56 µg/m3 for the RMSE, for NO2 and PM10, respectively, showing promise for efficient and inexpensive hybrid sensor air quality monitoring deployments.

Schlagwörter

Stichwörter der Autor:innen

air pollution monitoringair qualitycalibration propagationhybrid networklow-cost sensorsmachine learningsensor calibration

Autor:innen und Institutionen

  • School of Electrical Engineering, University of Belgrade, 11120 Belgrade, Serbia.
  • Innovation Center of the School of Electrical Engineering in Belgrade, 11120 Belgrade, Serbia.
  • DunavNET, DNET Labs, 21000 Novi Sad, Serbia.

ORCID-Profile: Dejan Drajic, Zoran Cica

Förderung

  • Ministry of Education, Science and Technological Development of the Republic of Serbia

Zitieren

APA

Vajs, I., Drajic, D., & Cica, Z. (2023). Data-Driven Machine Learning Calibration Propagation in A Hybrid Sensor Network for Air Quality Monitoring. Sensors, 23(5), 2815. https://doi.org/10.3390/s23052815

Vancouver

Vajs I, Drajic D, Cica Z. Data-Driven Machine Learning Calibration Propagation in A Hybrid Sensor Network for Air Quality Monitoring. Sensors. 2023;23(5):2815. doi:10.3390/s23052815

BibTeX
@article{Vajs2023,
  author = {Vajs, Ivan and Drajic, Dejan and Cica, Zoran},
  title = {Data-Driven Machine Learning Calibration Propagation in A Hybrid Sensor Network for Air Quality Monitoring},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {5},
  pages = {2815},
  doi = {10.3390/s23052815}
}
Kostenlos starten →