Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay
Sensors · 14.02.2023 · 23 (4) · 2160
DOI: 10.3390/s23042160 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 14.02.2023. Verfasst von Lidia Măgeruşan und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, 400293 Cluj-Napoca, Romania. Hauptthemen laut MEDLINE: Graphite. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerul Cercetării și Inovării, Ministry of Research, Innovation and Digitization, CNCS/CCCDI—UEFISCDI, “Nucleu” Programe within the National Plan for Research, Development and Innovation 2022–2027.
Abstract (Originalsprache)
Due to the recent increase in average living standards, food safety has caught public attention. It is necessary to conduct a qualitative and quantitative rapid test of prohibited food additives since the inclusion of food additives or the improper usage of synthetic dyes can negatively impact on the human health. Herein, a highly sensitive method for Sunset Yellow detection based on a glassy carbon electrode modified with few-layer graphenes was proposed. The electrochemical behavior of SY at the GR-exf/GCE modified surface was investigated by Cyclic Voltammetry, Square Wave Voltammetry, Electrochemical Impedance Spectroscopy and Amperometry. The influences of pH, scan rate, and interfering species were studied. Under optimized conditions, the developed sensor shows good linearity over a broad SY concentration range, e.g., 0.028–30 µM, with a low limit of detection (LOD = 0.0085 µM) and quantification (LOQ = 0.028 µM) (data obtained by amperometric technique). Furthermore, the modified electrode shows good selectivity, precision and sensitivity and has been successfully applied for SY quantification from commercially available pharmaceutical formulation as well as from candy bars and orange juice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, 400293 Cluj-Napoca, Romania.
ORCID-Profile: Lidia Măgeruşan, Stela Pruneanu
Förderung
- Ministerul Cercetării și Inovării
- Ministry of Research, Innovation and Digitization, CNCS/CCCDI—UEFISCDI
- “Nucleu” Programe within the National Plan for Research, Development and Innovation 2022–2027
Zitieren
APA
Măgeruşan, L., Pogăcean, F., Cozar, B. I., & Pruneanu, S. (2023). Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay. Sensors, 23(4), 2160. https://doi.org/10.3390/s23042160
Vancouver
Măgeruşan L, Pogăcean F, Cozar BI, Pruneanu S. Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay. Sensors. 2023;23(4):2160. doi:10.3390/s23042160
BibTeX
@article{Mgeruan2023,
author = {Măgeruşan, Lidia and Pogăcean, Florina and Cozar, Bogdan Ionuţ and Pruneanu, Stela},
title = {Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay},
journal = {Sensors},
year = {2023},
volume = {23},
number = {4},
pages = {2160},
doi = {10.3390/s23042160}
}
EUVIMED