Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 14.02.2023. Verfasst von Lidia Măgeruşan und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, 400293 Cluj-Napoca, Romania. Hauptthemen laut MEDLINE: Graphite. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerul Cercetării și Inovării, Ministry of Research, Innovation and Digitization, CNCS/CCCDI—UEFISCDI, “Nucleu” Programe within the National Plan for Research, Development and Innovation 2022–2027.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the recent increase in average living standards, food safety has caught public attention. It is necessary to conduct a qualitative and quantitative rapid test of prohibited food additives since the inclusion of food additives or the improper usage of synthetic dyes can negatively impact on the human health. Herein, a highly sensitive method for Sunset Yellow detection based on a glassy carbon electrode modified with few-layer graphenes was proposed. The electrochemical behavior of SY at the GR-exf/GCE modified surface was investigated by Cyclic Voltammetry, Square Wave Voltammetry, Electrochemical Impedance Spectroscopy and Amperometry. The influences of pH, scan rate, and interfering species were studied. Under optimized conditions, the developed sensor shows good linearity over a broad SY concentration range, e.g., 0.028–30 µM, with a low limit of detection (LOD = 0.0085 µM) and quantification (LOQ = 0.028 µM) (data obtained by amperometric technique). Furthermore, the modified electrode shows good selectivity, precision and sensitivity and has been successfully applied for SY quantification from commercially available pharmaceutical formulation as well as from candy bars and orange juice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteHumansCarbonElectrodesFood AdditivesAzo Compounds

Stichwörter der Autor:innen

electrochemical detectiongraphene-modified electrodesunset yellow

Substanzen

GraphiteCarbonFood Additives6-hydroxy-5-((p- sulfophenyl)azo)-2-naphthalenesulfonic acid disodium saltAzo Compounds

Autor:innen und Institutionen

  • National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, 400293 Cluj-Napoca, Romania.

ORCID-Profile: Lidia Măgeruşan, Stela Pruneanu

Förderung

  • Ministerul Cercetării și Inovării
  • Ministry of Research, Innovation and Digitization, CNCS/CCCDI—UEFISCDI
  • “Nucleu” Programe within the National Plan for Research, Development and Innovation 2022–2027

Zitieren

APA

Măgeruşan, L., Pogăcean, F., Cozar, B. I., & Pruneanu, S. (2023). Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay. Sensors, 23(4), 2160. https://doi.org/10.3390/s23042160

Vancouver

Măgeruşan L, Pogăcean F, Cozar BI, Pruneanu S. Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay. Sensors. 2023;23(4):2160. doi:10.3390/s23042160

BibTeX
@article{Mgeruan2023,
  author = {Măgeruşan, Lidia and Pogăcean, Florina and Cozar, Bogdan Ionuţ and Pruneanu, Stela},
  title = {Analytical Applicability of Graphene-Modified Electrode in Sunset Yellow Electrochemical Assay},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {4},
  pages = {2160},
  doi = {10.3390/s23042160}
}