EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Experiments of a Real-Time Bale Density Monitoring System Based on Dynamic Weighing

Jianjun Yin, Zhijian Chen, Chao Liu, Maile Zhou, Lu Liu iD

Sensors · 05.02.2023 · 23 (4) · 1778

DOI: 10.3390/s23041778 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 05.02.2023. Verfasst von Jianjun Yin und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Agricultural Engineering, Jiangsu University, Zhenjiang 222013, China. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jiangsu Provincial Key Laboratory of Agricultural Equipment and Intelligent High Tech-nology, National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bale density is one of the main performance indicators to measure the quality of baler operation. In this study, a real-time baler bale density monitoring system was designed for the problem of difficult real-time measurement of bale density on round balers. Firstly, a weighing calculation model for the rolling and sliding stage of the bale was established, and the dynamic characteristics during the contact between the bale and the inclined surface were analyzed based on ADAMS dynamics simulation. Then, a real-time monitoring system for the bale density based on the contact pressure of the inclined surface, attitude angle measurement and hydraulic monitoring of the cylinder was constructed, and the accuracy of the weighing model was confirmed. The system was used to observe and analyze the changes in the pitch angle of the carrier table and the oil pressure in the rod chamber of the backpack cylinder during the operation of the round baler. Finally, the monitoring system was calibrated and the dynamic calibration equations were obtained. The results show that the maximum error between the calculated value of the original weighing model and the actual weight was 3.63%, the maximum error of the calculated value of the weighing model corrected by the calibration equations was 3.40% and the measurement accuracy could be satisfied. The results show that the system was highly accurate and met the practical needs of bale weighing in the field.

Schlagwörter

Stichwörter der Autor:innen

bale balersbale densitydynamic weighingpressure detectionsignal processing

Autor:innen und Institutionen

  • School of Agricultural Engineering, Jiangsu University, Zhenjiang 222013, China.
  • Institute of Technology, Anhui Agricultural University, Hefei 230036, China.

ORCID-Profile: Lu Liu

Förderung

  • Jiangsu Provincial Key Laboratory of Agricultural Equipment and Intelligent High Tech-nology
  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangsu Province
  • Jiangsu Agriculture Science and Technology Innovation Fund
  • China Postdoctoral Science Foundation
  • Jiangsu Provincial Key Laboratory of Agricultural Equipment and Intelligent High Technology

Zitieren

APA

Yin, J., Chen, Z., Liu, C., Zhou, M., & Liu, L. (2023). Design and Experiments of a Real-Time Bale Density Monitoring System Based on Dynamic Weighing. Sensors, 23(4), 1778. https://doi.org/10.3390/s23041778

Vancouver

Yin J, Chen Z, Liu C, Zhou M, Liu L. Design and Experiments of a Real-Time Bale Density Monitoring System Based on Dynamic Weighing. Sensors. 2023;23(4):1778. doi:10.3390/s23041778

BibTeX
@article{Yin2023,
  author = {Yin, Jianjun and Chen, Zhijian and Liu, Chao and Zhou, Maile and Liu, Lu},
  title = {Design and Experiments of a Real-Time Bale Density Monitoring System Based on Dynamic Weighing},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {4},
  pages = {1778},
  doi = {10.3390/s23041778}
}
Kostenlos starten →