Practical Considerations for Using the NeoSpectra-Scanner Handheld Near-Infrared Reflectance Spectrometer to Predict the Nutritive Value of Undried Ensiled Forage
Sensors · 04.02.2023 · 23 (4) · 1750
DOI: 10.3390/s23041750 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.02.2023. Verfasst von Xiaoyu Feng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Agricultural and Biosystems Engineering, North Dakota State University, Fargo, ND 58105, USA. Hauptthemen laut MEDLINE: Detergents, Poaceae. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Food and Agriculture, USDA National Institute of Food and Agriculture.
Abstract (Originalsprache)
Prediction models of different types of forage were developed using a dataset of near-infrared reflectance spectra collected by three handheld NeoSpectra-Scanners and laboratory reference values for neutral detergent fiber (NDF), in vitro digestibility (IVTD), neutral detergent fiber digestibility (NDFD), acid detergent fiber (ADF), acid detergent lignin (ADL), crude protein (CP), Ash, and moisture content (MO) from a total of 555 undried ensiled corn, grass, and alfalfa samples. Data analyses and results of models developed in this study indicated that the scanning method significantly impacted the accuracy of the prediction of forage constituents, and using the NEO instrument with the sliding method improved calibration model performance (p < 0.05) for nearly all constituents. In general, poorer-performing models were more impacted by instrument-to-instrument variability. The exception, however, was moisture content (p = 0.02), where the validation set with an independent instrument resulted in an RMSEP of 2.39 compared to 1.44 where the same instruments were used for both calibration and validation. Validation model performance for NDF, IVTD, NDFD, ADL, ADF, Ash, CP, and moisture content were 4.18, 3.86, 6.14, 1.10, 2.75, 1.42, 2.71, and 1.67 for alfalfa-grass silage samples and 3.22, 2.21, 4.55, 0.38, 2.07, 0.50, 0.51, and 1.62 for corn silage, respectively. Based on the results of this study, the handheld spectrometer would be useful for predicting moisture content in undried and unground alfalfa-grass (R2 = 0.97) and corn (R2 = 0.93) forage samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Agricultural and Biosystems Engineering, North Dakota State University, Fargo, ND 58105, USA.
- Section of Soil and Crop Sciences, School of Integrative Plant Science, Cornell University, Ithaca, NY 14850, USA.
- Department of Animal Science, Cornell University, Ithaca, NY 14850, USA.
- Department of Biological Systems Engineering, University of Wisconsin, Madison, WI 53706, USA.
ORCID-Profile: Xiaoyu Feng, Debbie J R Cherney, Matthew F Digman
Förderung
- National Institute of Food and Agriculture
- USDA National Institute of Food and Agriculture
Zitieren
APA
Feng, X., Cherney, J. H., Cherney, D. J. R., & Digman, M. F. (2023). Practical Considerations for Using the NeoSpectra-Scanner Handheld Near-Infrared Reflectance Spectrometer to Predict the Nutritive Value of Undried Ensiled Forage. Sensors, 23(4), 1750. https://doi.org/10.3390/s23041750
Vancouver
Feng X, Cherney JH, Cherney DJR, Digman MF. Practical Considerations for Using the NeoSpectra-Scanner Handheld Near-Infrared Reflectance Spectrometer to Predict the Nutritive Value of Undried Ensiled Forage. Sensors. 2023;23(4):1750. doi:10.3390/s23041750
BibTeX
@article{Feng2023,
author = {Feng, Xiaoyu and Cherney, Jerry H and Cherney, Debbie J R and Digman, Matthew F},
title = {Practical Considerations for Using the NeoSpectra-Scanner Handheld Near-Infrared Reflectance Spectrometer to Predict the Nutritive Value of Undried Ensiled Forage},
journal = {Sensors},
year = {2023},
volume = {23},
number = {4},
pages = {1750},
doi = {10.3390/s23041750}
}