A GPS-Referenced Wavelength Standard for High-Precision Displacement Interferometry at λ = 633 nm
Sensors · 03.02.2023 · 23 (3) · 1734
DOI: 10.3390/s23031734 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 03.02.2023. Verfasst von Ulrike Blumröder und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Carl-Zeiss-Stiftung.
Abstract (Originalsprache)
Since the turn of the millennium, the development and commercial availability of optical frequency combs has led to a steadily increase of worldwide installed frequency combs and a growing interest in using them for industrial-related metrology applications. Especially, GPS-referenced frequency combs often serve as a “self-calibrating” length standard for laser wavelength calibration in many national metrology institutes with uncertainties better than u = 1 × 10−11. In this contribution, the application of a He-Ne laser source permanently disciplined to a GPS-referenced frequency comb for the interferometric measurements in a nanopositioning machine with a measuring volume of 200 mm × 200 mm × 25 mm (NPMM-200) is discussed. For this purpose, the frequency stability of the GPS-referenced comb is characterized by heterodyning with a diode laser referenced to an ultrastable cavity. Based on this comparison, an uncertainty of u = 9.2 × 10−12 (τ = 8 s, k = 2) for the GPS-referenced comb has been obtained. By stabilizing a tunable He-Ne source to a single comb line, the long-term frequency stability of the comb is transferred onto our gas lasers increasing their long-term stability by three orders of magnitude. Second, short-term fluctuations-related length measurement errors were reduced to a value that falls below the nominal resolving capabilities of our interferometers (ΔL/L = 2.9 × 10−11). Both measures make the influence of frequency distortions on the interferometric length measurement within the NPMM-200 negligible. Furthermore, this approach establishes a permanent link of interferometric length measurements to an atomic clock.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany.
- Precision Engineering Division, Physikalisch Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany.
ORCID-Profile: Ulrike Blumröder, Thomas Fröhlich, Thomas Kissinger, Ingo Ortlepp, Harald Bosse, Eberhard Manske
Förderung
- Carl-Zeiss-Stiftung
Zitieren
APA
Blumröder, U., Köchert, P., Fröhlich, T., Kissinger, T., Ortlepp, I., Flügge, J., Bosse, H., & Manske, E. (2023). A GPS-Referenced Wavelength Standard for High-Precision Displacement Interferometry at λ = 633 nm. Sensors, 23(3), 1734. https://doi.org/10.3390/s23031734
Vancouver
Blumröder U, Köchert P, Fröhlich T, Kissinger T, Ortlepp I, Flügge J, et al. A GPS-Referenced Wavelength Standard for High-Precision Displacement Interferometry at λ = 633 nm. Sensors. 2023;23(3):1734. doi:10.3390/s23031734
BibTeX
@article{Blumrder2023,
author = {Blumröder, Ulrike and Köchert, Paul and Fröhlich, Thomas and Kissinger, Thomas and Ortlepp, Ingo and Flügge, Jens and Bosse, Harald and Manske, Eberhard},
title = {A GPS-Referenced Wavelength Standard for High-Precision Displacement Interferometry at λ = 633 nm},
journal = {Sensors},
year = {2023},
volume = {23},
number = {3},
pages = {1734},
doi = {10.3390/s23031734}
}
EUVIMED