Reliability and Discriminative Validity of Wearable Sensors for the Quantification of Upper Limb Movement Disorders in Individuals with Dyskinetic Cerebral Palsy
Sensors · 2023
DOI: 10.3390/s23031574 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Inti Vanmechelen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Research Group for Neurorehabilitation (eNRGy), Department of Rehabilitation Sciences, KU Leuven, 8200 Bruges, Belgium. Hauptthemen laut MEDLINE: Cerebral Palsy, Movement Disorders, Dyskinesias, Wearable Electronic Devices. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Foundation - Flanders, Research Foundation Flanders.
Abstract (Originalsprache)
Background—Movement patterns in dyskinetic cerebral palsy (DCP) are characterized by abnormal postures and involuntary movements. Current evaluation tools in DCP are subjective and time-consuming. Sensors could yield objective information on pathological patterns in DCP, but their reliability has not yet been evaluated. The objectives of this study were to evaluate (i) reliability and (ii) discriminative ability of sensor parameters. Methods—Inertial measurement units were placed on the arm, forearm, and hand of individuals with and without DCP while performing reach-forward, reach-and-grasp-vertical, and reach-sideways tasks. Intra-class correlation coefficients (ICC) were calculated for reliability, and Mann–Whitney U-tests for between-group differences. Results—Twenty-two extremities of individuals with DCP (mean age 16.7 y) and twenty individuals without DCP (mean age 17.2 y) were evaluated. ICC values for all sensor parameters except jerk and sample entropy ranged from 0.50 to 0.98 during reach forwards/sideways and from 0.40 to 0.95 during reach-and-grasp vertical. Jerk and maximal acceleration/angular velocity were significantly higher for the DCP group in comparison with peers. Conclusions—This study was the first to assess the reliability of sensor parameters in individuals with DCP, reporting high between- and within-session reliability for the majority of the sensor parameters. These findings suggest that pathological movements of individuals with DCP can be reliably captured using a selection of sensor parameters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Group for Neurorehabilitation (eNRGy), Department of Rehabilitation Sciences, KU Leuven, 8200 Bruges, Belgium.
- Department of Rehabilitation Medicine, Amsterdam Movement Sciences, Amsterdam UMC, 1081 HZ Amsterdam, The Netherlands.
- Research Group for Neurorehabilitation (eNRGy), Department of Rehabilitation Sciences, KU Leuven, 3000 Leuven, Belgium.
- Research Group for Neurorehabilitation (eNRGy), Department of Rehabilitation Sciences, KU Leuven, 3212 Pellenberg, Belgium.
- Department of Biosystems, Measure, Model & Manage Bioresponses (M3-BIORES), Division of Animal and Human Health Engineering, KU Leuven, 3000 Leuven, Belgium.
ORCID-Profile: Inti Vanmechelen, Saranda Bekteshi, Helga Haberfehlner, Jean-Marie Aerts
Förderung
- Research Foundation - Flanders
- Research Foundation Flanders
Zitieren
APA
Vanmechelen, I., Bekteshi, S., Haberfehlner, H., Feys, H., Desloovere, K., Aerts, J. M., & Monbaliu, E. (2023). Reliability and Discriminative Validity of Wearable Sensors for the Quantification of Upper Limb Movement Disorders in Individuals with Dyskinetic Cerebral Palsy. Sensors. https://doi.org/10.3390/s23031574
Vancouver
Vanmechelen I, Bekteshi S, Haberfehlner H, Feys H, Desloovere K, Aerts JM, et al. Reliability and Discriminative Validity of Wearable Sensors for the Quantification of Upper Limb Movement Disorders in Individuals with Dyskinetic Cerebral Palsy. Sensors. 2023. doi:10.3390/s23031574
BibTeX
@article{Vanmechelen2023,
author = {Vanmechelen, Inti and Bekteshi, Saranda and Haberfehlner, Helga and Feys, Hilde and Desloovere, Kaat and Aerts, Jean-Marie and Monbaliu, Elegast},
title = {Reliability and Discriminative Validity of Wearable Sensors for the Quantification of Upper Limb Movement Disorders in Individuals with Dyskinetic Cerebral Palsy},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23031574}
}
EUVIMED