EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Personalized LSTM Models for ECG Lead Transformations Led to Fewer Diagnostic Errors Than Generalized Models: Deriving 12-Lead ECG from Lead II, V2, and V6

Prashanth Shyam Kumar iD, Mouli Ramasamy, Kamala Ramya Kallur, Pratyush Rai, Vijay K Varadan

Sensors · 26.01.2023 · 23 (3) · 1389

DOI: 10.3390/s23031389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 26.01.2023. Verfasst von Prashanth Shyam Kumar und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Engineering Science and Mechanics, The Pennsylvania State University, 212 Earth-Engineering Sciences Bldg, University Park, PA 1680…. Hauptthemen laut MEDLINE: Electrocardiography, Cardiovascular Diseases. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objective: The prevalence of chronic cardiovascular diseases (CVDs) has risen globally, nearly doubling from 1990 to 2019. ECG is a simple, non-invasive measurement that can help identify CVDs at an early and treatable stage. A multi-lead ECG, up to 15 leads in a wearable form factor, is desirable. We seek to derive multiple ECG leads from a select subset of leads so that the number of electrodes can be reduced in line with a patient-friendly wearable device. We further compare personalized derivations to generalized derivations.

Methods

Long-Short Term Memory (LSTM) networks using Lead II, V2, and V6 as input are trained to obtain generalized models using Bayesian Optimization for hyperparameter tuning for all patients and personalized models for each patient by applying transfer learning to the generalized models. We compare quantitatively using error metrics Root Mean Square Error (RMSE), R2, and Pearson correlation (ρ). We compare qualitatively by matching ECG interpretations of board-certified cardiologists.

Results

ECG interpretations from personalized models, when corrected for an intra-observer variance, were identical to the original ECGs, whereas generalized models led to errors. Mean performance values for generalized and personalized models were (RMSE-74.31 µV, R2-72.05, ρ-0.88) and (RMSE-26.27 µV, R2-96.38, ρ-0.98), respectively.

Conclusions

Diagnostic accuracy based on derived ECG is the most critical validation of ECG derivation methods. Personalized transformation should be sought to derive ECGs. Performing a personalized calibration step to wearable ECG systems and LSTM networks could yield ambulatory 15-lead ECGs with accuracy comparable to clinical ECGs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyCardiovascular DiseasesHumansBayes TheoremDiagnostic ErrorsElectrocardiography, Ambulatory

Stichwörter der Autor:innen

Bayesian OptimizationECGLSTM networkspersonalized medicinewearable devices

Autor:innen und Institutionen

  • The Department of Engineering Science and Mechanics, The Pennsylvania State University, 212 Earth-Engineering Sciences Bldg, University Park, PA 16802, USA.
  • Geisinger Medical Center, 100 North Academy Avenue, Danville, PA 17822, USA.
  • The Department of Biomedical Engineering, The University of Arkansas, 4183 Bell Engineering Center, Fayetteville, AR 72701, USA.
  • The Department of Neurosurgery, Milton S. Hershey Medical Center, 500 University Dr, Hershey, PA 17033, USA.

ORCID-Profile: Prashanth Shyam Kumar

Zitieren

APA

Shyam Kumar, P., Ramasamy, M., Kallur, K. R., Rai, P., & Varadan, V. K. (2023). Personalized LSTM Models for ECG Lead Transformations Led to Fewer Diagnostic Errors Than Generalized Models: Deriving 12-Lead ECG from Lead II, V2, and V6. Sensors, 23(3), 1389. https://doi.org/10.3390/s23031389

Vancouver

Shyam Kumar P, Ramasamy M, Kallur KR, Rai P, Varadan VK. Personalized LSTM Models for ECG Lead Transformations Led to Fewer Diagnostic Errors Than Generalized Models: Deriving 12-Lead ECG from Lead II, V2, and V6. Sensors. 2023;23(3):1389. doi:10.3390/s23031389

BibTeX
@article{ShyamKumar2023,
  author = {Shyam Kumar, Prashanth and Ramasamy, Mouli and Kallur, Kamala Ramya and Rai, Pratyush and Varadan, Vijay K},
  title = {Personalized LSTM Models for ECG Lead Transformations Led to Fewer Diagnostic Errors Than Generalized Models: Deriving 12-Lead ECG from Lead II, V2, and V6},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {3},
  pages = {1389},
  doi = {10.3390/s23031389}
}
Kostenlos starten →