EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A PVDF Receiver for Acoustic Monitoring of Microbubble-Mediated Ultrasound Brain Therapy

Yi Lin, Meaghan A O'Reilly, Kullervo Hynynen iD

Sensors · 2023

DOI: 10.3390/s23031369 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Yi Lin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada. Hauptthemen laut MEDLINE: Microbubbles, Brain. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, CIHR, National Institute of Biomedical Imaging and Bioengineering of the National Institute of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The real-time monitoring of spectral characteristics of microbubble (MB) acoustic emissions permits the prediction of increases in blood–brain barrier (BBB) permeability and of tissue damage in MB-mediated focused ultrasound (FUS) brain therapy. Single-element passive cavitation detectors provide limited spatial information regarding MB activity, greatly affecting the performance of acoustic control. However, an array of receivers can be used to spatially map cavitation events and thus improve treatment control. The spectral content of the acoustic emissions provides additional information that can be correlated with the bio-effects, and wideband receivers can thus provide the most complete spectral information. Here, we develop a miniature polyvinylidene fluoride (PVDF thickness = 110 μm, active area = 1.2 mm2) broadband receiver for the acoustic monitoring of MBs. The receiver has superior sensitivity (2.36–3.87 V/MPa) to those of a commercial fibre-optic hydrophone in the low megahertz frequency range (0.51–5.4 MHz). The receiver also has a wide −6 dB acceptance angle (54 degrees at 1.1 MHz and 13 degrees at 5.4 MHz) and the ability to detect subharmonic and higher harmonic MB emissions in phantoms. The overall acoustic performance of this low-cost receiver indicates its suitability for the eventual use within an array for MB monitoring and mapping in preclinical studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrobubblesBrainPolyvinylsBlood-Brain BarrierAcousticsFluorocarbon Polymers

Stichwörter der Autor:innen

blood–brain barrierfocused ultrasound (FUS)hydrophonemicromachiningtranscranial therapy

Substanzen

Polyvinylspolyvinylidene fluorideFluorocarbon Polymers

Autor:innen und Institutionen

  • Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.
  • Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
  • Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada.

ORCID-Profile: Kullervo Hynynen

Förderung

  • NIBIB NIH HHS
  • CIHR
  • National Institute of Biomedical Imaging and Bioengineering of the National Institute of Health
  • Canadian Institutes of Health Research
  • Temerty Chair in Focused Ultrasound Research at Sunnybrook Health Sciences Centre and the Canada Research Chair Program
  • Natural Sciences and Engineering Research Council of Alexander Graham Bell Canada Graduate Scholarship

Zitieren

APA

Lin, Y., O'Reilly, M. A., & Hynynen, K. (2023). A PVDF Receiver for Acoustic Monitoring of Microbubble-Mediated Ultrasound Brain Therapy. Sensors. https://doi.org/10.3390/s23031369

Vancouver

Lin Y, O'Reilly MA, Hynynen K. A PVDF Receiver for Acoustic Monitoring of Microbubble-Mediated Ultrasound Brain Therapy. Sensors. 2023. doi:10.3390/s23031369

BibTeX
@article{Lin2023,
  author = {Lin, Yi and O'Reilly, Meaghan A and Hynynen, Kullervo},
  title = {A PVDF Receiver for Acoustic Monitoring of Microbubble-Mediated Ultrasound Brain Therapy},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23031369}
}
Kostenlos starten →