Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting

Mohamed A A Hegazy iD, Myung Hye Cho, Min Hyoung Cho, Soo Yeol Lee iD

Sensors · 2023

DOI: 10.3390/s23031288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Mohamed A A Hegazy und 3 weiteren Autor:innen. Beteiligte Einrichtung: R&D Center, Ray, Seongnam-si 13494, Republic of Korea. Hauptthemen laut MEDLINE: Artifacts, Spiral Cone-Beam Computed Tomography. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metal artifacts in dental computed tomography (CT) images, caused by highly X-ray absorbing objects, such as dental implants or crowns, often more severely compromise image readability than in medical CT images. Since lower tube voltages are used for dental CTs in spite of the more frequent presence of metallic objects in the patient, metal artifacts appear more severely in dental CT images, and the artifacts often persist even after metal artifact correction. The direct sinogram correction (DSC) method, which directly corrects the sinogram using the mapping function derived by minimizing the sinogram inconsistency, works well in the case of mild metal artifacts, but it often fails to correct severe metal artifacts. We propose a modified DSC method to reduce severe metal artifacts, and we have tested it on human dental images. We first segment the metallic objects in the CT image, and then we forward-project the segmented metal mask to identify the metal traces in the projection data with computing the metal path length for the rays penetrating the metal mask. In the sinogram correction with the DSC mapping function, we apply the weighting proportional to the metal path length. We have applied the proposed method to the phantom and patient images taken at the X-ray tube voltage of 90 kVp. We observed that the proposed method outperforms the original DSC method when metal artifacts were severe. However, we need further extensive studies to verify the proposed method for various CT scan conditions with many more patient images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsSpiral Cone-Beam Computed TomographyHumansImage Processing, Computer-AssistedAlgorithmsTomography, X-Ray ComputedMetalsPhantoms, Imaging

Stichwörter der Autor:innen

beam hardeningdental CBCTdirect sinogram correctionmetal artifact reductionmetal segmentation

Substanzen

Metals

Autor:innen und Institutionen

  • R&D Center, Ray, Seongnam-si 13494, Republic of Korea.
  • Department of Biomedical Engineering, Kyung Hee University, Yongin-si 17104, Republic of Korea.

ORCID-Profile: Mohamed A A Hegazy, Soo Yeol Lee

Zitieren

APA

Hegazy, M. A. A., Cho, M. H., Cho, M. H., & Lee, S. Y. (2023). Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting. Sensors. https://doi.org/10.3390/s23031288

Vancouver

Hegazy MAA, Cho MH, Cho MH, Lee SY. Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting. Sensors. 2023. doi:10.3390/s23031288

BibTeX
@article{Hegazy2023,
  author = {Hegazy, Mohamed A A and Cho, Myung Hye and Cho, Min Hyoung and Lee, Soo Yeol},
  title = {Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23031288}
}
Kostenlos starten →