Circulant Singular Spectrum Analysis and Discrete Wavelet Transform for Automated Removal of EOG Artifacts from EEG Signals
Sensors · 21.01.2023 · 23 (3) · 1235
DOI: 10.3390/s23031235 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.01.2023. Verfasst von Jammisetty Yedukondalu und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronics Engineering, VIT-AP University, Amaravati 522237, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Wavelet Analysis, Artifacts. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Portable electroencephalogram (EEG) systems are often used in health care applications to record brain signals because their ease of use. An electrooculogram (EOG) is a common, low frequency, high amplitude artifact of the eye blink signal that might confuse disease diagnosis. As a result, artifact removal approaches in single EEG portable devices are in high demand. Materials: Dataset 2a from the BCI Competition IV was employed. It contains the EEG data from nine subjects. To determine the EOG effect, each session starts with 5 min of EEG data. This recording lasted for two minutes with the eyes open, one minute with the eyes closed, and one minute with eye movements. Methodology: This article presents the automated removal of EOG artifacts from EEG signals. Circulant Singular Spectrum Analysis (CiSSA) was used to decompose the EOG contaminated EEG signals into intrinsic mode functions (IMFs). Next, we identified the artifact signal components using kurtosis and energy values and removed them using 4-level discrete wavelet transform (DWT).
Results
The proposed approach was evaluated on synthetic and real EEG data and found to be effective in eliminating EOG artifacts while maintaining low frequency EEG information. CiSSA-DWT achieved the best signal to artifact ratio (SAR), mean absolute error (MAE), relative root mean square error (RRMSE), and correlation coefficient (CC) of 1.4525, 0.0801, 18.274, and 0.9883, respectively. Comparison: The developed technique outperforms existing artifact suppression techniques according to performance measures.
Conclusions
This advancement is important for brain science and can contribute as an initial pre-processing step for research related to EEG signals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronics Engineering, VIT-AP University, Amaravati 522237, Andhra Pradesh, India.
ORCID-Profile: Jammisetty Yedukondalu, Lakhan Dev Sharma
Zitieren
APA
Yedukondalu, J., & Sharma, L. D. (2023). Circulant Singular Spectrum Analysis and Discrete Wavelet Transform for Automated Removal of EOG Artifacts from EEG Signals. Sensors, 23(3), 1235. https://doi.org/10.3390/s23031235
Vancouver
Yedukondalu J, Sharma LD. Circulant Singular Spectrum Analysis and Discrete Wavelet Transform for Automated Removal of EOG Artifacts from EEG Signals. Sensors. 2023;23(3):1235. doi:10.3390/s23031235
BibTeX
@article{Yedukondalu2023,
author = {Yedukondalu, Jammisetty and Sharma, Lakhan Dev},
title = {Circulant Singular Spectrum Analysis and Discrete Wavelet Transform for Automated Removal of EOG Artifacts from EEG Signals},
journal = {Sensors},
year = {2023},
volume = {23},
number = {3},
pages = {1235},
doi = {10.3390/s23031235}
}
EUVIMED