An Improved Projector Calibration Method by Phase Mapping Based on Fringe Projection Profilometry

Yabin Liu iD, Bingwei Zhang iD, Xuewu Yuan, Junyi Lin, Kaiyong Jiang

Sensors · 19.01.2023 · 23 (3) · 1142

DOI: 10.3390/s23031142 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.01.2023. Verfasst von Yabin Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Key Laboratory of Special Energy Manufacturing, Huaqiao University, Xiamen 361021, China. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fujian Province Industry-University-Research Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aiming at the problem of the low accuracy of projector calibration in a structured light system, an improved projector calibration method is proposed in this paper. One of the key ideas is to estimate the sub-pixel coordinates in the projector image plane using local random sample consensus (RANSAC). A bundle adjustment (BA) algorithm is adopted to optimize the calibration parameters to further improve the accuracy and robustness of the projector calibration. After system calibration and epipolar rectification, the mapping relationship between the pixel coordinates and the absolute phase in the projector image plane is established by using cubic polynomial fitting, and the disparity is rapidly solved by using the mapping relationship, which not only ensures the measurement accuracy, but also improves the measurement efficiency. The experimental results demonstrated that the average re-projection error after optimization is reduced to 0.03 pixels, and the proposed method is suitable for high-speed 3D reconstruction without the time-consuming homogenous point searching.

Schlagwörter

Stichwörter der Autor:innen

cubic polynomial fittingfringe projection profilometrylocal random sample consensusphase mappingprojector calibration

Autor:innen und Institutionen

  • Fujian Key Laboratory of Special Energy Manufacturing, Huaqiao University, Xiamen 361021, China.
  • Xiamen Key Laboratory of Digital Vision Measurement, Huaqiao University, Xiamen 361021, China.

ORCID-Profile: Yabin Liu, Bingwei Zhang

Förderung

  • Fujian Province Industry-University-Research Program

Zitieren

APA

Liu, Y., Zhang, B., Yuan, X., Lin, J., & Jiang, K. (2023). An Improved Projector Calibration Method by Phase Mapping Based on Fringe Projection Profilometry. Sensors, 23(3), 1142. https://doi.org/10.3390/s23031142

Vancouver

Liu Y, Zhang B, Yuan X, Lin J, Jiang K. An Improved Projector Calibration Method by Phase Mapping Based on Fringe Projection Profilometry. Sensors. 2023;23(3):1142. doi:10.3390/s23031142

BibTeX
@article{Liu2023,
  author = {Liu, Yabin and Zhang, Bingwei and Yuan, Xuewu and Lin, Junyi and Jiang, Kaiyong},
  title = {An Improved Projector Calibration Method by Phase Mapping Based on Fringe Projection Profilometry},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {3},
  pages = {1142},
  doi = {10.3390/s23031142}
}
Kostenlos starten →