iCanClean Improves Independent Component Analysis of Mobile Brain Imaging with EEG
Sensors · 2023
DOI: 10.3390/s23020928 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Colton B Gonsisko und 2 weiteren Autor:innen. Beteiligte Einrichtung: J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA. Hauptthemen laut MEDLINE: Electroencephalography, Brain. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Motion artifacts hinder source-level analysis of mobile electroencephalography (EEG) data using independent component analysis (ICA). iCanClean is a novel cleaning algorithm that uses reference noise recordings to remove noisy EEG subspaces, but it has not been formally tested in a parameter sweep. The goal of this study was to test iCanClean’s ability to improve the ICA decomposition of EEG data corrupted by walking motion artifacts. Our primary objective was to determine optimal settings and performance in a parameter sweep (varying the window length and r2 cleaning aggressiveness). High-density EEG was recorded with 120 + 120 (dual-layer) EEG electrodes in young adults, high-functioning older adults, and low-functioning older adults. EEG data were decomposed by ICA after basic preprocessing and iCanClean. Components well-localized as dipoles (residual variance < 15%) and with high brain probability (ICLabel > 50%) were marked as ‘good’. We determined iCanClean’s optimal window length and cleaning aggressiveness to be 4-s and r2 = 0.65 for our data. At these settings, iCanClean improved the average number of good components from 8.4 to 13.2 (+57%). Good performance could be maintained with reduced sets of noise channels (12.7, 12.2, and 12.0 good components for 64, 32, and 16 noise channels, respectively). Overall, iCanClean shows promise as an effective method to clean mobile EEG data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA.
ORCID-Profile: Colton B Gonsisko, Daniel P Ferris, Ryan J Downey
Förderung
- NIH HHS
- National Institutes of Health
Zitieren
APA
Gonsisko, C. B., Ferris, D. P., & Downey, R. J. (2023). iCanClean Improves Independent Component Analysis of Mobile Brain Imaging with EEG. Sensors. https://doi.org/10.3390/s23020928
Vancouver
Gonsisko CB, Ferris DP, Downey RJ. iCanClean Improves Independent Component Analysis of Mobile Brain Imaging with EEG. Sensors. 2023. doi:10.3390/s23020928
BibTeX
@article{Gonsisko2023,
author = {Gonsisko, Colton B and Ferris, Daniel P and Downey, Ryan J},
title = {iCanClean Improves Independent Component Analysis of Mobile Brain Imaging with EEG},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23020928}
}
EUVIMED