Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control
Sensors · 10.01.2023 · 23 (2) · 791
DOI: 10.3390/s23020791 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 10.01.2023. Verfasst von Camila Rodrigues-Carvalho und 8 weiteren Autor:innen. Beteiligte Einrichtung: Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), 28002 Madrid, Spain. Hauptthemen laut MEDLINE: Exoskeleton Device. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, Spanish National Research Council, Ministerio de Ciencia e Innovación.
Abstract (Originalsprache)
Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH’s protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human–exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), 28002 Madrid, Spain.
- Systems Engineering and Automation Department, Carlos III University of Madrid, 28903 Madrid, Spain.
- Electronic Technology Department, Rey Juan Carlos University, 28933 Móstoles, Spain.
- CAR-UPM Associated Unit, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
- Center for Clinical Neuroscience, Hospital Los Madroños, 28690 Madrid, Spain.
ORCID-Profile: Camila Rodrigues-Carvalho, David Pinto-Fernández, Clara Sanz-Morere, Filipe Oliveira Barroso, Susana Borromeo, Cristina Rodríguez-Sánchez, Juan C Moreno, Antonio J Del-Ama
Förderung
- European Union
- Spanish National Research Council
- Ministerio de Ciencia e Innovación
- European Union Next Generation
- European Union’s Horizon 2020 research and innovation program
- CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+)
- Spanish MCIN/AEI/
- European Union NextGenerationEU/PRTR
Zitieren
APA
Rodrigues-Carvalho, C., Fernández-García, M., Pinto-Fernández, D., Sanz-Morere, C., Barroso, F. O., Borromeo, S., Rodríguez-Sánchez, C., Moreno, J. C., & Del-Ama, A. J. (2023). Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control. Sensors, 23(2), 791. https://doi.org/10.3390/s23020791
Vancouver
Rodrigues-Carvalho C, Fernández-García M, Pinto-Fernández D, Sanz-Morere C, Barroso FO, Borromeo S, et al. Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control. Sensors. 2023;23(2):791. doi:10.3390/s23020791
BibTeX
@article{RodriguesCarvalho2023,
author = {Rodrigues-Carvalho, Camila and Fernández-García, Marvin and Pinto-Fernández, David and Sanz-Morere, Clara and Barroso, Filipe Oliveira and Borromeo, Susana and Rodríguez-Sánchez, Cristina and Moreno, Juan C and Del-Ama, Antonio J},
title = {Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control},
journal = {Sensors},
year = {2023},
volume = {23},
number = {2},
pages = {791},
doi = {10.3390/s23020791}
}
EUVIMED