MobileNet-SVM: A Lightweight Deep Transfer Learning Model to Diagnose BCH Scans for IoMT-Based Imaging Sensors
Sensors · 06.01.2023 · 23 (2) · 656
DOI: 10.3390/s23020656 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.01.2023. Verfasst von Roseline Oluwaseun Ogundokun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Multimedia Engineering, Kaunas University of Technology, 44249 Kaunas, Lithuania. Hauptthemen laut MEDLINE: Support Vector Machine, Internet of Things. Die Arbeit wurde bisher 65-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Many individuals worldwide pass away as a result of inadequate procedures for prompt illness identification and subsequent treatment. A valuable life can be saved or at least extended with the early identification of serious illnesses, such as various cancers and other life-threatening conditions. The development of the Internet of Medical Things (IoMT) has made it possible for healthcare technology to offer the general public efficient medical services and make a significant contribution to patients’ recoveries. By using IoMT to diagnose and examine BreakHis v1 400× breast cancer histology (BCH) scans, disorders may be quickly identified and appropriate treatment can be given to a patient. Imaging equipment having the capability of auto-analyzing acquired pictures can be used to achieve this. However, the majority of deep learning (DL)-based image classification approaches are of a large number of parameters and unsuitable for application in IoMT-centered imaging sensors. The goal of this study is to create a lightweight deep transfer learning (DTL) model suited for BCH scan examination and has a good level of accuracy. In this study, a lightweight DTL-based model “MobileNet-SVM”, which is the hybridization of MobileNet and Support Vector Machine (SVM), for auto-classifying BreakHis v1 400× BCH images is presented. When tested against a real dataset of BreakHis v1 400× BCH images, the suggested technique achieved a training accuracy of 100% on the training dataset. It also obtained an accuracy of 91% and an F1-score of 91.35 on the test dataset. Considering how complicated BCH scans are, the findings are encouraging. The MobileNet-SVM model is ideal for IoMT imaging equipment in addition to having a high degree of precision. According to the simulation findings, the suggested model requires a small computation speed and time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Multimedia Engineering, Kaunas University of Technology, 44249 Kaunas, Lithuania.
- Department of Computer Science, Landmark University, Omu Aran 251103, Kwara, Nigeria.
- Department of Computer Science and Communication, Østfold University College, 1757 Halden, Norway.
- Department of Mathematical Sciences, Augustine University Ilara-Epe, Lagos 106103, Lagos, Nigeria.
ORCID-Profile: Roseline Oluwaseun Ogundokun
Zitieren
APA
Ogundokun, R. O., Misra, S., Akinrotimi, A. O., & Ogul, H. (2023). MobileNet-SVM: A Lightweight Deep Transfer Learning Model to Diagnose BCH Scans for IoMT-Based Imaging Sensors. Sensors, 23(2), 656. https://doi.org/10.3390/s23020656
Vancouver
Ogundokun RO, Misra S, Akinrotimi AO, Ogul H. MobileNet-SVM: A Lightweight Deep Transfer Learning Model to Diagnose BCH Scans for IoMT-Based Imaging Sensors. Sensors. 2023;23(2):656. doi:10.3390/s23020656
BibTeX
@article{Ogundokun2023,
author = {Ogundokun, Roseline Oluwaseun and Misra, Sanjay and Akinrotimi, Akinyemi Omololu and Ogul, Hasan},
title = {MobileNet-SVM: A Lightweight Deep Transfer Learning Model to Diagnose BCH Scans for IoMT-Based Imaging Sensors},
journal = {Sensors},
year = {2023},
volume = {23},
number = {2},
pages = {656},
doi = {10.3390/s23020656}
}
EUVIMED