EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and In-Orbit Validation of a Novel Compact Bidirectional Trapezoidal Reflector for X-Band Spaceborne SAR Absolute Radiometric Calibration

Shiyu Sun, Yu Wang, Huijuan Li, Xin Zhang

Remote Sensing · 03.03.2026 · 18 (5) · 770

DOI: 10.3390/rs18050770 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 03.03.2026. Verfasst von Shiyu Sun und 3 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spaceborne synthetic aperture radar (SAR) absolute radiometric calibration relies on point targets with a known radar cross-section (RCS), such as triangular trihedral corner reflectors (TTCRs). Traditionally, radiometric calibration using TTCRs requires precise alignment of the corner reflector (CR) boresight to the radar line-of-sight (LOS), leading to frequent field operations and high labor dependency. In this study, a novel compact bidirectional trapezoidal CR is proposed to eliminate such alignment reorientations. The novel CR adopts three design considerations: a scalene shape to optimize the boresight elevation angle and enhance the peak RCS; a bidirectional configuration with azimuth fine-tuning to align with the radar LOS for both ascending and descending passes; and trapezoidal plate trimming to reduce the volume and weight without sacrificing RCS performance. An in-orbit validation is conducted in Xi’an, China, using the SuperView Neo 2-03 satellite. The results demonstrate that the imaging quality of the bidirectional trapezoidal CRs is comparable to that of conventional TTCRs, with all the parameters meeting system specifications. The radiometric calibration constant of the bidirectional trapezoidal CR differs from that of the conventional TTCR by no more than 0.27 dB, with a total uncertainty of ~0.33 dB (1σ)—demonstrating that it achieves equivalent radiometric calibration accuracy to TTCRs. The experiment confirms the feasibility and engineering applicability of the bidirectional trapezoidal CR for X-band SAR radiometric calibration.

Förderung

  • The National Natural Science Foundation of China

Zitieren

APA

Sun, S., Wang, Y., Li, H., & Zhang, X. (2026). Design and In-Orbit Validation of a Novel Compact Bidirectional Trapezoidal Reflector for X-Band Spaceborne SAR Absolute Radiometric Calibration. Remote Sensing, 18(5), 770. https://doi.org/10.3390/rs18050770

Vancouver

Sun S, Wang Y, Li H, Zhang X. Design and In-Orbit Validation of a Novel Compact Bidirectional Trapezoidal Reflector for X-Band Spaceborne SAR Absolute Radiometric Calibration. Remote Sensing. 2026;18(5):770. doi:10.3390/rs18050770

BibTeX
@article{Sun2026,
  author = {Sun, Shiyu and Wang, Yu and Li, Huijuan and Zhang, Xin},
  title = {Design and In-Orbit Validation of a Novel Compact Bidirectional Trapezoidal Reflector for X-Band Spaceborne SAR Absolute Radiometric Calibration},
  journal = {Remote Sensing},
  year = {2026},
  volume = {18},
  number = {5},
  pages = {770},
  doi = {10.3390/rs18050770}
}
Kostenlos starten →