An Operational Ground-Based Vicarious Radiometric Calibration Method for Thermal Infrared Sensors: A Case Study of GF-5A WTI
Remote Sensing · 16.01.2026 · 18 (2) · 302
DOI: 10.3390/rs18020302 ↗Kurz gefasst
Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 16.01.2026. Verfasst von Jingwei Bai und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Laboratory of Target Cognition and Application Technology.
Abstract (Originalsprache)
High-resolution TIR missions require sustained and well-characterized radiometric accuracy to support applications such as land surface temperature retrieval, drought monitoring, and surface energy budget analysis. To address this need, we develop an operational and automated ground-based vicarious radiometric calibration framework for TIR sensors and demonstrate its performance using the Wide-swath Thermal Infrared Imager (WTI) onboard Gaofen-5 01A (GF-5A). Three arid Gobi calibration sites were selected by integrating Moderate Resolution Imaging Spectroradiometer (MODIS) cloud products, Shuttle Radar Topography Mission (SRTM)-derived topography, and WTI-based radiometric uniformity metrics to ensure low cloud cover, flat terrain, and high spatial homogeneity. Automated ground stations deployed at Golmud, Dachaidan, and Dunhuang have continuously recorded 1 min contact surface temperature since October 2023. Field-measured emissivity spectra, Integrated Global Radiosonde Archive (IGRA) radiosonde profiles, and MODTRAN (MODerate resolution atmospheric TRANsmission) v5.2 simulations were combined to compute top-of-atmosphere (TOA) radiances, which were subsequently collocated with WTI imagery. After data screening and gain-stratified regression, linear calibration coefficients were derived for each TIR band. Based on 189 scenes from February–July 2024, all four bands exhibit strong linearity (R-squared greater than 0.979). Validation using 45 independent scenes yields a mean brightness–temperature root-mean-square error (RMSE) of 0.67 K. A full radiometric-chain uncertainty budget—including contact temperature, emissivity, atmospheric profiles, and radiative transfer modeling—results in a combined standard uncertainty of 1.41 K. The proposed framework provides a low-maintenance, traceable, and high-frequency solution for the long-term on-orbit radiometric calibration of GF-5A WTI and establishes a reproducible pathway for future TIR missions requiring sustained calibration stability.
Förderung
- Key Laboratory of Target Cognition and Application Technology
Zitieren
APA
Bai, J., Bao, Y., Zhou, G., Zhang, S., Guan, H., Zhang, M., Zhao, Y., & Jiang, K. (2026). An Operational Ground-Based Vicarious Radiometric Calibration Method for Thermal Infrared Sensors: A Case Study of GF-5A WTI. Remote Sensing, 18(2), 302. https://doi.org/10.3390/rs18020302
Vancouver
Bai J, Bao Y, Zhou G, Zhang S, Guan H, Zhang M, et al. An Operational Ground-Based Vicarious Radiometric Calibration Method for Thermal Infrared Sensors: A Case Study of GF-5A WTI. Remote Sensing. 2026;18(2):302. doi:10.3390/rs18020302
BibTeX
@article{Bai2026,
author = {Bai, Jingwei and Bao, Yunfei and Zhou, Guangyao and Zhang, Shuyan and Guan, Hong and Zhang, Mingmin and Zhao, Yongchao and Jiang, Kang},
title = {An Operational Ground-Based Vicarious Radiometric Calibration Method for Thermal Infrared Sensors: A Case Study of GF-5A WTI},
journal = {Remote Sensing},
year = {2026},
volume = {18},
number = {2},
pages = {302},
doi = {10.3390/rs18020302}
}
EUVIMED