EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Radiometric Cross-Calibration of GF6-PMS and WFV Sensors with Sentinel 2-MSI and Landsat 9-OLI2

Hengyang Wang, Zhaoning He, Shuang Wang, Yachao Zhang, Hongzhao Tang

Remote Sensing · 29.05.2024 · 16 (11) · 1949

DOI: 10.3390/rs16111949 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 29.05.2024. Verfasst von Hengyang Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A panchromatic and multispectral sensor (PMS) and a wide-field-of-view (WFV) sensor were fitted aboard the Gaofen6 (GF6) satellite, which was launched on 2 June 2018. This study used the Landsat9-Operational Land Imager 2 and Sentinel2-Multispectral Instrument as reference sensors to perform radiometric cross-calibration on GF6-PMS and WFV data at the Dunhuang calibration site. The four selected sensor images were all acquired on the same day. The results indicate that: the calibration results between different reference sensors can be controlled within 3%, with the maximum difference from the official coefficients being 8.78%. A significant difference was observed between the coefficients obtained by different reference sensors when spectral band adjustment factor (SBAF) correction was not performed; from the two sets of validation results, the maximum mean relative difference in the near-infrared band was 9.46%, with the WFV sensor showing better validation results. The validation of calibration coefficients based on synchronous ground observation data and the analysis of the impact of different SBAF methods on the calibration results indicated that Landsat9 is more suitable as a reference sensor for radiometric cross-calibration of GF6-PMS and WFV.

Förderung

  • National Key R&D Program of China

Zitieren

APA

Wang, H., He, Z., Wang, S., Zhang, Y., & Tang, H. (2024). Radiometric Cross-Calibration of GF6-PMS and WFV Sensors with Sentinel 2-MSI and Landsat 9-OLI2. Remote Sensing, 16(11), 1949. https://doi.org/10.3390/rs16111949

Vancouver

Wang H, He Z, Wang S, Zhang Y, Tang H. Radiometric Cross-Calibration of GF6-PMS and WFV Sensors with Sentinel 2-MSI and Landsat 9-OLI2. Remote Sensing. 2024;16(11):1949. doi:10.3390/rs16111949

BibTeX
@article{Wang2024,
  author = {Wang, Hengyang and He, Zhaoning and Wang, Shuang and Zhang, Yachao and Tang, Hongzhao},
  title = {Radiometric Cross-Calibration of GF6-PMS and WFV Sensors with Sentinel 2-MSI and Landsat 9-OLI2},
  journal = {Remote Sensing},
  year = {2024},
  volume = {16},
  number = {11},
  pages = {1949},
  doi = {10.3390/rs16111949}
}
Kostenlos starten →