EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monopulse Parameter Estimation for FDA-MIMO Radar under Mainlobe Deception Jamming

Hao Chen, Rongfeng Li, Hui Chen, Qizhe Qu, Bilei Zhou, Binbin Li, Yongliang Wang

Remote Sensing · 09.08.2023 · 15 (16) · 3947

DOI: 10.3390/rs15163947 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 09.08.2023. Verfasst von Hao Chen und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiple input multiple output with frequency diversity array (FDA-MIMO) radar has unique advantages in mainlobe deception jamming suppression and target location. However, if the training sample contains the target signal, it will lead to poor jamming suppression performance and large target measurement error. To deal with the problem, a method of coarse target location in the time domain is proposed based on the cumulative sampling analysis. Taking full advantages of the strongest correlation characteristic between the expected steering vector and the true target, the feature vector and feature value corresponding to the true target are found after feature decomposition. The time domain location of the target is roughly estimated during the cumulative sampling analysis from near to far. Then, a pure jamming training sample can be obtained by avoiding the location. Noise subspace projection algorithm is used to measure the angle and range of the target while suppressing mainlobe jamming. The simulation results show that the proposed method can roughly estimate the target location in the time domain when the mainlobe deception jamming completely covers the target. Compared with conventional methods, the performance of jamming suppression and target localization error are closer to the performance of ideal sampling.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, H., Li, R., Chen, H., Qu, Q., Zhou, B., Li, B., & Wang, Y. (2023). Monopulse Parameter Estimation for FDA-MIMO Radar under Mainlobe Deception Jamming. Remote Sensing, 15(16), 3947. https://doi.org/10.3390/rs15163947

Vancouver

Chen H, Li R, Chen H, Qu Q, Zhou B, Li B, et al. Monopulse Parameter Estimation for FDA-MIMO Radar under Mainlobe Deception Jamming. Remote Sensing. 2023;15(16):3947. doi:10.3390/rs15163947

BibTeX
@article{Chen2023,
  author = {Chen, Hao and Li, Rongfeng and Chen, Hui and Qu, Qizhe and Zhou, Bilei and Li, Binbin and Wang, Yongliang},
  title = {Monopulse Parameter Estimation for FDA-MIMO Radar under Mainlobe Deception Jamming},
  journal = {Remote Sensing},
  year = {2023},
  volume = {15},
  number = {16},
  pages = {3947},
  doi = {10.3390/rs15163947}
}
Kostenlos starten →