EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Calibration Method of Multi-Channel Spatially Varying Amplitude-Phase Inconsistency Errors in Airborne Array TomoSAR

Dawei Wang, Fubo Zhang, Longyong Chen, Zhenhua Li, Ling Yang

Remote Sensing · 09.06.2023 · 15 (12) · 3032

DOI: 10.3390/rs15123032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 09.06.2023. Verfasst von Dawei Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Airborne array tomographic synthetic aperture radar (TomoSAR) can acquire three-dimensional (3D) information of the observed scene in a single pass. In the process of airborne array TomoSAR data imaging, due to the disturbance of factors such as inconsistent antenna patterns and baseline errors, there are spatially varying amplitude-phase inconsistency errors in the multi-channel Single-Look-Complex (SLC) images. The existence of the errors degrades the quality of the 3D imaging results, which suffer from positioning errors, stray points, and spurious targets. In this paper, a new calibration method based on multiple prominent points is proposed to calibrate the errors of amplitude-phase inconsistency. Firstly, the prominent points are selected from the multi-channel SLC data. Then, the subspace decomposition method and maximum interference spectrum method are used to extract the multi-channel amplitude-phase inconsistency information at each point. The last step is to fit the varying curve and to compensate for the errors. The performance of the method is verified using actual data. The experimental results show that compared with the traditional fixed amplitude-phase inconsistency calibration method, the proposed method can effectively calibrate spatially varying amplitude-phase inconsistency errors, thus improving on the accuracy of 3D reconstruction results for large-scale scenes.

Förderung

  • National Key R&D Program of China

Zitieren

APA

Wang, D., Zhang, F., Chen, L., Li, Z., & Yang, L. (2023). The Calibration Method of Multi-Channel Spatially Varying Amplitude-Phase Inconsistency Errors in Airborne Array TomoSAR. Remote Sensing, 15(12), 3032. https://doi.org/10.3390/rs15123032

Vancouver

Wang D, Zhang F, Chen L, Li Z, Yang L. The Calibration Method of Multi-Channel Spatially Varying Amplitude-Phase Inconsistency Errors in Airborne Array TomoSAR. Remote Sensing. 2023;15(12):3032. doi:10.3390/rs15123032

BibTeX
@article{Wang2023,
  author = {Wang, Dawei and Zhang, Fubo and Chen, Longyong and Li, Zhenhua and Yang, Ling},
  title = {The Calibration Method of Multi-Channel Spatially Varying Amplitude-Phase Inconsistency Errors in Airborne Array TomoSAR},
  journal = {Remote Sensing},
  year = {2023},
  volume = {15},
  number = {12},
  pages = {3032},
  doi = {10.3390/rs15123032}
}
Kostenlos starten →