Denoising and Accuracy Evaluation of ICESat-2/ATLAS Photon Data for Nearshore Waters Based on Improved Local Distance Statistics
Remote Sensing · 29.05.2023 · 15 (11) · 2828
DOI: 10.3390/rs15112828 ↗Kurz gefasst
Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 29.05.2023. Verfasst von Junfeng Xie und 6 weiteren Autor:innen. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Postgraduate Research & Practice Innovation Program of Jiangsu Province, National Natural Science Foundation of China, Special Funds for Creative Research.
Abstract (Originalsprache)
The second-generation spaceborne LiDAR-Ice, Cloud and Land Elevation Satellite-2 (ICESat-2) carries the Advanced Topographic Laser Altimeter System (ATLAS), which can penetrate a certain depth of water, and is one of the important means to obtain the water depth information of nearshore water. However, due to the influence of the atmospheric environment, water quality and color, the system itself and other factors, the photon point cloud introduces survey noise, which restricts the survey accuracy and reliability of nearshore water depth. Therefore, in this study, we presented a photon denoising algorithm for layered processing of submarine surface. Firstly, rough denoising of the original photon data was completed by smoothing filtering. Then, elevation histogram statistics were carried out on the photon data, two peaks of the histogram were fitted by a double Gaussian function, and the intersection of two curves was then taken to separate the water surface and underwater photons. The surface photons were denoised by the DBSCAN clustering algorithm. Then according to the distribution characteristics of underwater signal photons, a single-photon point cloud filtering bathymetric method was proposed based on improved local distance statistics (LDSBM), which was used for fine denoising of underwater point cloud data. Finally, the Gaussian function was used to fit the frequency histogram, and the signal photons were screened to extract the water depth information. In this study, 13 groups of the ATL03 dataset from the Xisha Islands, the St. Thomas and the Acklins Island were used for denoising. The denoising results were compared with the signal photons manually marked and the signal photons extracted by the official built-in method (OM). The experimental results showed that, compared with the official method results of ATL03, the LDSBM had a higher F value (comprehensive evaluation index), with an average of more than 96.70%. In conclusion, the proposed underwater single-photon point cloud filtering bathymetric method was superior to the traditional algorithm and could recover terrain information accurately.
Förderung
- Postgraduate Research & Practice Innovation Program of Jiangsu Province
- National Natural Science Foundation of China
- Special Funds for Creative Research
- Innovative Youth Talents Program, Ministry of Natural Resources of the People’s Republic of China
- National Key R&D Program of China
Zitieren
APA
Xie, J., Zhong, J., Mo, F., Liu, R., Li, X., Yang, X., & Zeng, J. (2023). Denoising and Accuracy Evaluation of ICESat-2/ATLAS Photon Data for Nearshore Waters Based on Improved Local Distance Statistics. Remote Sensing, 15(11), 2828. https://doi.org/10.3390/rs15112828
Vancouver
Xie J, Zhong J, Mo F, Liu R, Li X, Yang X, et al. Denoising and Accuracy Evaluation of ICESat-2/ATLAS Photon Data for Nearshore Waters Based on Improved Local Distance Statistics. Remote Sensing. 2023;15(11):2828. doi:10.3390/rs15112828
BibTeX
@article{Xie2023,
author = {Xie, Junfeng and Zhong, Jincheng and Mo, Fan and Liu, Ren and Li, Xiang and Yang, Xiaomeng and Zeng, Junze},
title = {Denoising and Accuracy Evaluation of ICESat-2/ATLAS Photon Data for Nearshore Waters Based on Improved Local Distance Statistics},
journal = {Remote Sensing},
year = {2023},
volume = {15},
number = {11},
pages = {2828},
doi = {10.3390/rs15112828}
}
EUVIMED