EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation and Analysis of Remotely Sensed Water Vapor from the NASA VIIRS/SNPP Product in Mainland China Using GPS Data

Linghao Zhou, Lei Fan, Chuang Shi

Remote Sensing · 10.03.2023 · 15 (6) · 1528

DOI: 10.3390/rs15061528 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Remote Sensing, online erschienen am 10.03.2023. Verfasst von Linghao Zhou und 2 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Precipitable water vapor (PWV) is a vitally important factor in atmospheric circulation. PWV is significant for forecasting extreme weather and understanding the dynamics of climate change. Comprehensively evaluating the performance of newly proposed remotely sensed water vapor products is crucial for guaranteeing their suitability for futural PWV applications. In this study, the accuracy of the recently established remotely sensed water vapor product from the Visible Infrared Imaging Radiometer Suite (VIIRS) satellite sensor on the Suomi National Polar-orbiting Partnership (SNPP) (VIIRS-PWV) platform within various regions of mainland China was evaluated via the PWV from Global Positioning System (GPS) observations. The GPS-derived PWV from 231 stations of the Crustal Movement Observation Network of China (CMONOC) from 2012 to 2018 was obtained through precise point positioning (PPP) techniques. The results showed that the mean value of the correlation coefficient (CC), the mean bias (MB), and the root-mean-square error (RMSE) between the VIIRS-PWV and the GPS-PWV were 0.92, −1.6 mm, and 4.7 mm, respectively. These values were comparable with the results of the PWV data derived from the Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectroradiometer (MODIS) products. This indicates that the VIIRS product could provide PWV data with satisfactory accuracy for large-area scientific applications. Moreover, the MB and RMSE of the differences between the GPS-PWV and VIIRS-PWV showed obvious seasonal variations. The VIIRS-PWV generally performed better in winter (with the MB and RMSE values of 0.1 mm and 2.3 mm) than in summer (with the MB and RMSE values of −4.4 and 7.0 mm). Analysis among different regions revealed that the Central South (CS) region of China attained the largest mean RMSE value of 6.3 mm, and the North West (NW) region attained the smallest mean RMSE value of 3.8 mm. In addition, the southern region of China obtained a mean RMSE value of 5.6 mm, while that for the northern region of China was 3.9 mm. This indicates that the VIIRS-PWV has better accuracy within the northern region of China than within the southern region.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhou, L., Fan, L., & Shi, C. (2023). Evaluation and Analysis of Remotely Sensed Water Vapor from the NASA VIIRS/SNPP Product in Mainland China Using GPS Data. Remote Sensing, 15(6), 1528. https://doi.org/10.3390/rs15061528

Vancouver

Zhou L, Fan L, Shi C. Evaluation and Analysis of Remotely Sensed Water Vapor from the NASA VIIRS/SNPP Product in Mainland China Using GPS Data. Remote Sensing. 2023;15(6):1528. doi:10.3390/rs15061528

BibTeX
@article{Zhou2023,
  author = {Zhou, Linghao and Fan, Lei and Shi, Chuang},
  title = {Evaluation and Analysis of Remotely Sensed Water Vapor from the NASA VIIRS/SNPP Product in Mainland China Using GPS Data},
  journal = {Remote Sensing},
  year = {2023},
  volume = {15},
  number = {6},
  pages = {1528},
  doi = {10.3390/rs15061528}
}
Kostenlos starten →