EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From Biological Gait to CPG Network Design: A Biomechanics-Driven Model-Selection Pipeline

Daniel Arriaga-Ventura, Riccardo Cespi, Javier Izquierdo-Reyes, Stefano Di Gennaro, Rogelio Bustamante-Bello

Robotics · 22.10.2026 · 15 (11) · 208

DOI: 10.3390/robotics15110208 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Robotics, online erschienen am 22.10.2026. Verfasst von Daniel Arriaga-Ventura und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Secretaría de Ciencia, Humanidades, Tecnología e Innovación (SECIHTI), Mexico, Instituto Tecnológico y de Estudios Superiores de Monterrey.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transferring observed gait coordination into executable Central Pattern Generator (CPG) specifications remains challenging because networks are often tuned empirically without systematic links to measured biomechanics. This study presents a biomechanics-driven pipeline using the walking gait of the fiddler crab Uca pugnax. Marker-based video analysis provided mean dominant frequency, movement amplitudes, phase relations, and coordination hierarchy. These descriptors defined oscillator roles, reference hierarchy, coupling topology, phase targets, communication direction, and an eight-oscillator architecture. A coarse-to-fine procedure selected parameters for phase-only Kuramoto and limit-cycle Hopf networks under unidirectional and bidirectional communication. Offline simulations assessed amplitude, phase-offset, convergence, dominant-frequency, and residual-oscillation errors. Kuramoto converged in 0.098 s under both communication schemes, with mean phase errors of 0.40% and 0.08%, respectively; both communication configurations preserved the prescribed gait frequency, with the bidirectional network producing 0.522 Hz. Hopf preserved frequency within 0.02% and 0.01%; the selected unidirectional configuration achieved the lower phase error, whereas the selected bidirectional configuration yielded a lower mean amplitude error (0.32% versus 2.87%), with longer convergence and residual oscillations. The pipeline provides a reproducible route from biological measurements to computational CPG design and model selection before physical deployment; robot validation is outside the present scope.

Förderung

  • Secretaría de Ciencia, Humanidades, Tecnología e Innovación (SECIHTI), Mexico
  • Instituto Tecnológico y de Estudios Superiores de Monterrey

Zitieren

APA

Arriaga-Ventura, D., Cespi, R., Izquierdo-Reyes, J., Gennaro, S. D., & Bustamante-Bello, R. (2026). From Biological Gait to CPG Network Design: A Biomechanics-Driven Model-Selection Pipeline. Robotics, 15(11), 208. https://doi.org/10.3390/robotics15110208

Vancouver

Arriaga-Ventura D, Cespi R, Izquierdo-Reyes J, Gennaro SD, Bustamante-Bello R. From Biological Gait to CPG Network Design: A Biomechanics-Driven Model-Selection Pipeline. Robotics. 2026;15(11):208. doi:10.3390/robotics15110208

BibTeX
@article{ArriagaVentura2026,
  author = {Arriaga-Ventura, Daniel and Cespi, Riccardo and Izquierdo-Reyes, Javier and Gennaro, Stefano Di and Bustamante-Bello, Rogelio},
  title = {From Biological Gait to CPG Network Design: A Biomechanics-Driven Model-Selection Pipeline},
  journal = {Robotics},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {208},
  doi = {10.3390/robotics15110208}
}
Kostenlos starten →