EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Case Report: Transient Complete Atrioventricular Block During Coronary Sinus Reducer Implantation: An Unexpected Complication

Gianluca Pagnoni iD, Alberto Monello, Luca Rossi, Daniela Aschieri, Marco Loffi iD

Reports · 23.06.2026 · 9 (3) · 197

DOI: 10.3390/reports9030197 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Reports, online erschienen am 23.06.2026. Verfasst von Gianluca Pagnoni und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Unit of Emergency Department, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Clinical Significance: The Coronary Sinus Reducer (CSR) is a percutaneous therapeutic option for patients with refractory angina who are unsuitable for further myocardial revascularization. The procedure has a generally favorable safety profile, with a low rate of reported procedural complications. To our knowledge, major atrioventricular (AV) conduction disturbances during CSR implantation have not been previously described. This case highlights a rare but clinically relevant intraprocedural complication; Case Presentation: A 71-year-old man with multivessel coronary artery disease and previous coronary artery bypass grafting was referred for CSR implantation because of refractory angina despite optimal medical therapy and lack of further revascularization options. The procedure was performed via a right jugular venous approach. Baseline electrocardiography showed right bundle branch block and findings consistent with previous inferior myocardial infarction, without definite criteria for left anterior fascicular block. During coronary sinus cannulation, the patient developed transient complete AV block, resulting in an approximately 8–10-second ventricular pause without a stable ventricular escape rhythm. The conduction disturbance resolved after catheter withdrawal and repositioning. Given the severity of the event, a temporary transvenous pacemaker was inserted via the right femoral vein, allowing safe completion of CSR implantation. At three-month follow-up, angina had improved from Canadian Cardiovascular Society class III to class I, and no recurrent advanced AV block was documented; Conclusions: Transient complete AV block may occur during CSR implantation, particularly during coronary sinus manipulation and possibly in patients with pre-existing conduction disease. Careful catheter handling, prompt recognition of conduction disturbances, and immediate availability of temporary pacing support should be considered in selected high-risk patients undergoing CSR implantation.

Schlagwörter

Stichwörter der Autor:innen

Coronary Sinus Reducercomplete atrioventricular blockrefractory anginatemporary pacing

Autor:innen und Institutionen

  • Cardiology Unit of Emergency Department, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy.

ORCID-Profile: Gianluca Pagnoni, Marco Loffi

Zitieren

APA

Pagnoni, G., Monello, A., Rossi, L., Aschieri, D., & Loffi, M. (2026). Case Report: Transient Complete Atrioventricular Block During Coronary Sinus Reducer Implantation: An Unexpected Complication. Reports, 9(3), 197. https://doi.org/10.3390/reports9030197

Vancouver

Pagnoni G, Monello A, Rossi L, Aschieri D, Loffi M. Case Report: Transient Complete Atrioventricular Block During Coronary Sinus Reducer Implantation: An Unexpected Complication. Reports. 2026;9(3):197. doi:10.3390/reports9030197

BibTeX
@article{Pagnoni2026,
  author = {Pagnoni, Gianluca and Monello, Alberto and Rossi, Luca and Aschieri, Daniela and Loffi, Marco},
  title = {Case Report: Transient Complete Atrioventricular Block During Coronary Sinus Reducer Implantation: An Unexpected Complication},
  journal = {Reports},
  year = {2026},
  volume = {9},
  number = {3},
  pages = {197},
  doi = {10.3390/reports9030197}
}
Kostenlos starten →