EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Are Water-Based Algorithms Still Adequate for Dose Calculation in Modern HDR Interventional Radiotherapy? A Review with Special Focus on 3D-Printed Applicators and Heterogeneous Materials

Enrico Rosa, Bruno Fionda, Maria Vaccaro, Valentina Lancellotta, Elisa Placidi, Maria Concetta La Milia, Gabriele Ciasca, Pierpaolo Dragonetti, Andre Karius, Frank-André Siebert, Luca Tagliaferri, Marco De Spirito

Radiation · 02.08.2026 · 6 (3) · 29

DOI: 10.3390/radiation6030029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation, online erschienen am 02.08.2026. Verfasst von Enrico Rosa und 11 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-dose-rate interventional radiotherapy (HDR IRT) relies on accurate dose calculations to ensure safe and effective treatment. The AAPM TG-43 formalism, based on homogeneous water assumptions, has long been the clinical standard, but the growing use of patient-specific applicators and heterogeneous materials challenges its accuracy. Materials and Methods: A literature narrative review was performed using PubMed and Scopus to identify studies comparing TG-43 and model-based dose calculation algorithms (MBDCAs), including deterministic methods (ACE, Acuros BV) and Monte Carlo simulations. Thirty-five studies were selected and qualitatively analyzed.

Results

TG-43 yielded higher dose compared with MBDCAs, particularly in the presence of tissue heterogeneities, air gaps, shielding materials, and limited scatter conditions. Differences ranged from 2 to 5% in relatively homogeneous settings to more than 10–20% in complex geometries such as superficial mould treatments and head-and-neck IRT. Model-based approaches showed better agreement with Monte Carlo simulations and experimental measurements, especially in contact HDR IRT and applications involving 3D-printed applicators.

Conclusion

While TG-43 remains clinically established and widely used, its limitations are increasingly evident in modern personalized HDR IRT. Model-based dose calculation algorithms provide greater dosimetric accuracy and should be progressively integrated into clinical practice, particularly in treatments involving significant heterogeneities.

Zitieren

APA

Rosa, E., Fionda, B., Vaccaro, M., Lancellotta, V., Placidi, E., Milia, M. C. L., Ciasca, G., Dragonetti, P., Karius, A., Siebert, F., Tagliaferri, L., & Spirito, M. D. (2026). Are Water-Based Algorithms Still Adequate for Dose Calculation in Modern HDR Interventional Radiotherapy? A Review with Special Focus on 3D-Printed Applicators and Heterogeneous Materials. Radiation, 6(3), 29. https://doi.org/10.3390/radiation6030029

Vancouver

Rosa E, Fionda B, Vaccaro M, Lancellotta V, Placidi E, Milia MCL, et al. Are Water-Based Algorithms Still Adequate for Dose Calculation in Modern HDR Interventional Radiotherapy? A Review with Special Focus on 3D-Printed Applicators and Heterogeneous Materials. Radiation. 2026;6(3):29. doi:10.3390/radiation6030029

BibTeX
@article{Rosa2026,
  author = {Rosa, Enrico and Fionda, Bruno and Vaccaro, Maria and Lancellotta, Valentina and Placidi, Elisa and Milia, Maria Concetta La and Ciasca, Gabriele and Dragonetti, Pierpaolo and Karius, Andre and Siebert, Frank-André and Tagliaferri, Luca and Spirito, Marco De},
  title = {Are Water-Based Algorithms Still Adequate for Dose Calculation in Modern HDR Interventional Radiotherapy? A Review with Special Focus on 3D-Printed Applicators and Heterogeneous Materials},
  journal = {Radiation},
  year = {2026},
  volume = {6},
  number = {3},
  pages = {29},
  doi = {10.3390/radiation6030029}
}
Kostenlos starten →