Development of a Xylene-Free Sample Preparation Protocol for Quantitative Proteomics of Clinically Relevant Formaldehyde-Fixed Paraffin-Embedded Needle Biopsy Samples
Proteomes · 14.06.2026 · 14 (2) · 30
DOI: 10.3390/proteomes14020030 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Proteomes, online erschienen am 14.06.2026. Verfasst von Gontse Mabuse Moagi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Proteomics Core Facility, Department of Biochemistry and Molecular Biology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, H-4032 Debrec…. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GINOP, Department of Higher Education and Training, Tempus Public Foundation.
Abstract (Originalsprache)
Background
Fresh frozen tissues are considered the gold standard for proteomic analyses due to their superior preservation of protein integrity; however, their use is limited by the logistical and financial requirements of long-term cold storage. Formaldehyde-fixed paraffin-embedded (FFPE) tissues provide a practical alternative, owing to their stability and widespread availability in clinical settings. A critical step in FFPE proteomics is deparaffinization, which traditionally relies on organic solvents such as xylene, along with the efficient reversal of formaldehyde-induced crosslinks.
Methods
In this study, we evaluated multiple FFPE protein extraction and digestion workflows including chaotropic, surfactant-based, and detergent-free approaches in combination with xylene-free deparaffinization strategies, using label-free data-independent acquisition (DIA) LC-MS/MS.
Results
Among the tested methods, a chaotropic, reductant, and surfactant-free in-solution digestion workflow demonstrated robust protein and peptide recovery. A modified version of this protocol further improved peptide coverage while maintaining comparable protein depth. The applicability of the optimized workflow was assessed using FFPE needle biopsy samples from control, hepatic steatosis, and liver fibrosis groups. Exploratory proteomic patterns were observed across conditions, with hepatic steatosis associated with early activation of stress-response pathways, while fibrosis showed evidence suggesting altered lipid metabolism.
Conclusions
Overall, this study presents a simple, xylene-free, and MS-compatible workflow for FFPE proteomics that is suitable for low-input clinical samples and may support broader application of archival tissues in proteomic research.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Proteomics Core Facility, Department of Biochemistry and Molecular Biology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, H-4032 Debrecen, Hungary.
- Doctoral School of Molecular Cell and Immune Biology, University of Debrecen, Egyetem tér 1, H-4032 Debrecen, Hungary.
- Health Care Service and Units, Department of Pathology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, H-4032 Debrecen, Hungary.
- Department of Medical Chemistry, Albert Szent-Györgyi Medical School, University of Szeged, Dóm Square 8, H-6720 Szeged, Hungary.
- MTA-HUN-REN TTK Lendület (Momentum) Glycan Biomarker Research Group, HUN-REN Research Centre for Natural Sciences, Magyar Tudósok Körútja 2, H-1117 Budapest, Hungary.
ORCID-Profile: Gontse Mabuse Moagi, Gábor Kecskeméti, Zoltán Szabó, Lilla Turiák, Éva Csősz
Förderung
- GINOP
- Department of Higher Education and Training
- Tempus Public Foundation
- Tempus Public Foundation-Stipendium Hungaricum Scholarship
- DHET Academic Support Funding
- Ministry of Culture and Innovation of Hungary from the National Research
Zitieren
APA
Moagi, G. M., Beke, L., Méhes, G., Kecskeméti, G., Szabó, Z., Turiák, L., & Csősz, É. (2026). Development of a Xylene-Free Sample Preparation Protocol for Quantitative Proteomics of Clinically Relevant Formaldehyde-Fixed Paraffin-Embedded Needle Biopsy Samples. Proteomes, 14(2), 30. https://doi.org/10.3390/proteomes14020030
Vancouver
Moagi GM, Beke L, Méhes G, Kecskeméti G, Szabó Z, Turiák L, et al. Development of a Xylene-Free Sample Preparation Protocol for Quantitative Proteomics of Clinically Relevant Formaldehyde-Fixed Paraffin-Embedded Needle Biopsy Samples. Proteomes. 2026;14(2):30. doi:10.3390/proteomes14020030
BibTeX
@article{Moagi2026,
author = {Moagi, Gontse Mabuse and Beke, Lívia and Méhes, Gábor and Kecskeméti, Gábor and Szabó, Zoltán and Turiák, Lilla and Csősz, Éva},
title = {Development of a Xylene-Free Sample Preparation Protocol for Quantitative Proteomics of Clinically Relevant Formaldehyde-Fixed Paraffin-Embedded Needle Biopsy Samples},
journal = {Proteomes},
year = {2026},
volume = {14},
number = {2},
pages = {30},
doi = {10.3390/proteomes14020030}
}
EUVIMED