EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biomechanical and Functional Outcomes in Transtibial Amputees Using the Transtibial Mercer Universal Prosthesis (MUP®): A 1-Year Longitudinal Study

Trung T. Le, Craig T. McMahan, Ha V. Vo, Scott C. E. Brandon

Prosthesis · 01.07.2026 · 8 (7) · 69

DOI: 10.3390/prosthesis8070069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Prosthesis, online erschienen am 01.07.2026. Verfasst von Trung T. Le und 3 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mercer On Mission–Prosthetic Program and by the Natural Sciences and Engineering Research Council of Canada.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Mercer Universal Prosthesis (MUP), designed with a default “neutral” (vertical) socket alignment, was developed to simplify transtibial prosthetic fitting, reduce labor costs, and improve access to prosthetic care in low-resource settings.

Methods

This present longitudinal study evaluated biomechanical and functional outcomes at baseline, 6 months, and 12 months in 20 transtibial amputees fitted with the MUP.

Results

Functional outcomes, assessed using the SF-36, showed significant improvement in overall health scores at 12 months (p < 0.001), while physical function and energy/fatigue domains remained unchanged (p = 0.686 and p = 0.211, respectively). Biomechanically, sagittal kinematics, measured using inertial motion capture, revealed significant limb × time interactions for hip flexion, knee flexion, and ankle plantarflexion. At 6 months, maximum hip flexion (−7°, p = 0.008) and knee flexion (−11°, p = 0.005) of the prosthetic limb were decreased versus baseline. At 12 months, the only observed difference was increased maximum ankle plantarflexion of the intact limb (+5° vs. baseline, p = 0.016). Muscle effort, quantified via the integral of EMG throughout the gait cycle, did not differ significantly between prosthetic and intact limbs across time points. Gait symmetry index (GSI) scores for hip, knee, and ankle range of motion trended toward gradual improvement but without statistical significance (p > 0.05).

Conclusions

The MUP performance was maintained over 12 months, with stable biomechanical performance and meaningful quality-of-life gains. These findings support its potential as a cost-effective solution to expand prosthetic accessibility in low- and middle-income countries.

Förderung

  • Mercer On Mission–Prosthetic Program and by the Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Le, T. T., McMahan, C. T., Vo, H. V., & Brandon, S. C. E. (2026). Biomechanical and Functional Outcomes in Transtibial Amputees Using the Transtibial Mercer Universal Prosthesis (MUP®): A 1-Year Longitudinal Study. Prosthesis, 8(7), 69. https://doi.org/10.3390/prosthesis8070069

Vancouver

Le TT, McMahan CT, Vo HV, Brandon SCE. Biomechanical and Functional Outcomes in Transtibial Amputees Using the Transtibial Mercer Universal Prosthesis (MUP®): A 1-Year Longitudinal Study. Prosthesis. 2026;8(7):69. doi:10.3390/prosthesis8070069

BibTeX
@article{Le2026,
  author = {Le, Trung T. and McMahan, Craig T. and Vo, Ha V. and Brandon, Scott C. E.},
  title = {Biomechanical and Functional Outcomes in Transtibial Amputees Using the Transtibial Mercer Universal Prosthesis (MUP®): A 1-Year Longitudinal Study},
  journal = {Prosthesis},
  year = {2026},
  volume = {8},
  number = {7},
  pages = {69},
  doi = {10.3390/prosthesis8070069}
}
Kostenlos starten →