EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous Control

Yunpeng Huang, Nan Wang, Dapeng Zhang, Zhenyu Liu, Yuanyi Zhang, Yongjun Zhou, Xueshen Zhao, Yuqing Qu

Processes · 23.11.2026 · 14 (23) · 3760

DOI: 10.3390/pr14233760 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 23.11.2026. Verfasst von Yunpeng Huang und 7 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of State Grid Jibei Electric Power Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To investigate the reverse frequency overshoot and transient oscillations that may arise in an islanded hydro-storage microgrid using conventional P–ω virtual synchronous control under specific parameter settings, this paper analyzes the active-power–frequency dynamic external characteristics of the microgrid under P–ω2 virtual synchronous control. An active-power–frequency dynamic model coupling the physical inertia of the hydro-turbine synchronous generator and the virtual inertia of the grid-forming energy-storage converter is established. The power–frequency regulation characteristics of P–ω and P–ω2 control are compared, and the effects of virtual inertia and virtual damping on the active-power–frequency dynamic external characteristics are analyzed. A joint inertia–damping parameterization is then formulated, and the effects of parameter scaling and load-disturbance magnitude on the active-power–frequency dynamic external characteristics of the microgrid are evaluated using the maximum frequency deviation, rate of change of frequency, and dynamic recovery time. PSCAD/EMTDC simulation results show that, compared with conventional P–ω control, P–ω2 control mitigates reverse frequency overshoot and transient oscillations during the recovery process. The inertia–damping parameter combination and load-disturbance magnitude significantly affect the system frequency dynamics, thereby validating the established model and the corresponding external-characteristic analysis.

Förderung

  • Science and Technology Project of State Grid Jibei Electric Power Co., Ltd.

Zitieren

APA

Huang, Y., Wang, N., Zhang, D., Liu, Z., Zhang, Y., Zhou, Y., Zhao, X., & Qu, Y. (2026). Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous Control. Processes, 14(23), 3760. https://doi.org/10.3390/pr14233760

Vancouver

Huang Y, Wang N, Zhang D, Liu Z, Zhang Y, Zhou Y, et al. Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous Control. Processes. 2026;14(23):3760. doi:10.3390/pr14233760

BibTeX
@article{Huang2026,
  author = {Huang, Yunpeng and Wang, Nan and Zhang, Dapeng and Liu, Zhenyu and Zhang, Yuanyi and Zhou, Yongjun and Zhao, Xueshen and Qu, Yuqing},
  title = {Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous Control},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {23},
  pages = {3760},
  doi = {10.3390/pr14233760}
}
Kostenlos starten →