Effects of Dual-Auger Composite Borehole Placement on Upper-Corner Methane Control: Numerical Modeling and Field Monitoring
Processes · 18.11.2026 · 14 (22) · 3709
DOI: 10.3390/pr14223709 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 18.11.2026. Verfasst von Zhipeng Che und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Shanxi Key Laboratory of Life Rescue Access Construction Technology and Equipment for Confined Space Emergency Response.
Abstract (Originalsprache)
Methane (CH4) migration from the goaf can cause accumulation in the upper corner of U-ventilated working faces. Composite-borehole placement and methane control were investigated at working face 81506 of Huayang No. 2 Mine. A heterogeneous porous-medium model was developed in Ansys Fluent using user-defined functions (UDFs) to describe spatially varying porosity and flow resistance. Five borehole-to-corner distances (10, 20, 30, 40, and 50 m) were evaluated. A composite borehole was constructed by coordinated dual-auger drilling at the selected distance of 40 m, followed by 60 days of field monitoring. At 40 m, simulated mean and maximum upper-corner CH4 concentrations were 0.2475% and 0.8659%, respectively, and mixed-gas mass flow from the goaf toward the working face decreased by 47.77% relative to the no-drainage case. At 50 m, the maximum concentration exceeded 1.0%, making 40 m the largest tested distance meeting this criterion. In the field, mean and maximum upper-corner CH4 concentrations decreased by 48.43% and 39.73%, respectively, to 0.557% and 0.88%. Composite-borehole drainage was thus effective under the tested conditions, with local maximum concentration serving as a key placement criterion.
Förderung
- National Natural Science Foundation of China
- Shanxi Key Laboratory of Life Rescue Access Construction Technology and Equipment for Confined Space Emergency Response
Zitieren
APA
Che, Z., Zhang, X., Qiao, X., Zhang, L., Lv, X., Song, J., & Li, W. (2026). Effects of Dual-Auger Composite Borehole Placement on Upper-Corner Methane Control: Numerical Modeling and Field Monitoring. Processes, 14(22), 3709. https://doi.org/10.3390/pr14223709
Vancouver
Che Z, Zhang X, Qiao X, Zhang L, Lv X, Song J, et al. Effects of Dual-Auger Composite Borehole Placement on Upper-Corner Methane Control: Numerical Modeling and Field Monitoring. Processes. 2026;14(22):3709. doi:10.3390/pr14223709
BibTeX
@article{Che2026,
author = {Che, Zhipeng and Zhang, Xinghua and Qiao, Xiaoguang and Zhang, Lulu and Lv, Xiaobo and Song, Jintang and Li, Wenjun},
title = {Effects of Dual-Auger Composite Borehole Placement on Upper-Corner Methane Control: Numerical Modeling and Field Monitoring},
journal = {Processes},
year = {2026},
volume = {14},
number = {22},
pages = {3709},
doi = {10.3390/pr14223709}
}