Power-Circle Vulnerability Assessment and Two-Stage IPSO-Based Multi-STATCOM Allocation for Fine Voltage Regulation in Distribution Networks

Jie Zhang, Yujie Du, Yonfei Ma, Junjie Xia, Xuan Wang, Qiuyang Li, Zhibin Hu, Yulong Qiao, Yuanyuan Wang

Processes · 13.11.2026 · 14 (22) · 3669

DOI: 10.3390/pr14223669 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 13.11.2026. Verfasst von Jie Zhang und 8 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, State Grid Qinghai Electric Power Company, Hunan Provincial Outstanding Youth Fund Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A two-stage improved particle swarm optimization (IPSO) framework is proposed for multi-STATCOM siting and sizing in radial distribution networks, together with a power-circle external-tangency margin for independent electrical-vulnerability assessment. The power-circle margin is formulated from branch active- and reactive-power circle relationships, aggregated by the arithmetic mean of incident-branch margins to avoid topological-degree bias, and cross-checked against Q–V continuation-power-flow results and load-level sensitivity. STATCOM planning minimizes the annual cost of active-power losses, annualized device investment, and operation and maintenance under hard voltage constraints. In the first optimization stage, two installation locations and coarse capacities are searched jointly; the second stage fixes the selected locations and continuously refines the capacities. On the IEEE 33-bus system, the power-circle and Q–V rankings show a Spearman correlation of 0.8644 and 90% Top-10 overlap. Deterministic enumeration identifies Bus 7 with 3.6689 Mvar as the best single-STATCOM solution, whereas the optimal dual configuration is 0.5583 Mvar at Bus 16 and 1.1571 Mvar at Bus 30. The dual solution reduces annual cost by 38.86% relative to the optimal single-device solution and reduces active-power loss to 0.1402 MW while satisfying all normal-operation voltage limits. Across 30 independent runs on the dual-device problem, the proposed IPSO attains the highest location-pair and global-solution success rates (33.33%) and the lowest mean objective value among six compared algorithms. Under restored N − 1 contingencies, the normal-operation economic optimum improves post-contingency voltage performance but is capacity-limited; with the locations fixed, a total rating of 6.5693 Mvar is required to satisfy all 31 restorable contingencies, revealing the trade-off between normal-operation economy and post-contingency voltage compliance.

Förderung

  • National Natural Science Foundation of China
  • State Grid Qinghai Electric Power Company
  • Hunan Provincial Outstanding Youth Fund Project

Zitieren

APA

Zhang, J., Du, Y., Ma, Y., Xia, J., Wang, X., Li, Q., Hu, Z., Qiao, Y., & Wang, Y. (2026). Power-Circle Vulnerability Assessment and Two-Stage IPSO-Based Multi-STATCOM Allocation for Fine Voltage Regulation in Distribution Networks. Processes, 14(22), 3669. https://doi.org/10.3390/pr14223669

Vancouver

Zhang J, Du Y, Ma Y, Xia J, Wang X, Li Q, et al. Power-Circle Vulnerability Assessment and Two-Stage IPSO-Based Multi-STATCOM Allocation for Fine Voltage Regulation in Distribution Networks. Processes. 2026;14(22):3669. doi:10.3390/pr14223669

BibTeX
@article{Zhang2026,
  author = {Zhang, Jie and Du, Yujie and Ma, Yonfei and Xia, Junjie and Wang, Xuan and Li, Qiuyang and Hu, Zhibin and Qiao, Yulong and Wang, Yuanyuan},
  title = {Power-Circle Vulnerability Assessment and Two-Stage IPSO-Based Multi-STATCOM Allocation for Fine Voltage Regulation in Distribution Networks},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {22},
  pages = {3669},
  doi = {10.3390/pr14223669}
}
Kostenlos starten →