Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions
Processes · 13.11.2026 · 14 (22) · 3668
DOI: 10.3390/pr14223668 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 13.11.2026. Verfasst von Xiaobin Wei und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Power Engineering Consulting Group.
Abstract (Originalsprache)
The transient responses of GIL-overhead line hybrid transmission systems during lightning and short-circuit faults directly affect insulation performance, equipment thermal stability, and grounding safety, particularly under high-resistivity soil conditions. However, research on enclosure fault current distribution and its spatial distribution of grounding currents along multipoint-grounded GIL systems under such conditions remains limited. To address this issue, an electromagnetic transient model of a 500 kV GIL-overhead line hybrid transmission system is established to investigate fault responses in high-resistivity soil conditions. The effects of short-circuit types, fault locations, and enclosure grounding spacing on grounding current distribution are analyzed. The results indicate that increased grounding impedance aggravates lightning-induced transient overvoltage. Under short-circuit faults, grounding currents along the GIL exhibit a U-shaped distribution, characterized by higher currents at both ends and lower currents in the middle. The peak local grounding current reaches 42.22 kA during a single-phase-to-ground fault in the middle section of the GIL. This study provides a basis for identifying critical grounding points, selecting adverse fault conditions, and comparing grounding configurations in hybrid transmission systems, as well as for grounding-lead thermal stability verification and grounding safety assessment.
Förderung
- China Power Engineering Consulting Group
Zitieren
APA
Wei, X., Liang, M., Fang, Y., Fan, Y., Ding, X., & Zhang, X. (2026). Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions. Processes, 14(22), 3668. https://doi.org/10.3390/pr14223668
Vancouver
Wei X, Liang M, Fang Y, Fan Y, Ding X, Zhang X. Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions. Processes. 2026;14(22):3668. doi:10.3390/pr14223668
BibTeX
@article{Wei2026,
author = {Wei, Xiaobin and Liang, Ming and Fang, Yu and Fan, Yan and Ding, Xiaofei and Zhang, Xueqin},
title = {Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil Conditions},
journal = {Processes},
year = {2026},
volume = {14},
number = {22},
pages = {3668},
doi = {10.3390/pr14223668}
}
EUVIMED