EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Physico-Analytical Modeling of an Industrial Low-Temperature Natural Gas Separation Line with Three-Section Cold Recovery and Propane Cooling

Akmalbek Abdusalomov, Husan Igamberdiyev, Shaxzod Amirov, Uktam Mamirov, Jasur Sevinov, Mukhriddin Mukhiddinov, Sabina Umirzakova, Teag Keun Whangbo

Processes · 11.11.2026 · 14 (22) · 3645

DOI: 10.3390/pr14223645 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 11.11.2026. Verfasst von Akmalbek Abdusalomov und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tashkent State Technical University of Uzbekistan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study develops and tests a first-principles dynamic model of an industrial low-temperature separation (LTS) train with three-section cold recovery and propane refrigeration (LTS-4 line, Mubarek Gas Processing Plant). Mass, energy and hydraulic balances of the coolers, the recuperators 20T-01 and 20T-02A–C (including tube-wall heat capacity), the separators and the propane evaporator are coupled with Peng–Robinson phase-equilibrium relations into an index-1 differential-algebraic system with 13 + 12N states. A 58-state thermal core was calibrated on 5 h and validated on 7 h of 2 min supervisory control and data acquisition (SCADA) records that include a 19% throughput step. The 20C-01 gas temperature was predicted with a validation root-mean-square error of 0.49 K (R2 = 0.93), against 1.89 K for a persistence predictor. The linearized core is asymptotically stable; the wall heat capacity, 14.5 times the gas holdup, raises the slowest time constant from 2.4 to 15.2 min. The return-gas loop amplifies the evaporator response to propane-temperature changes by 33%, and one cell per section underestimates the cascade effectiveness (0.64 versus 0.81). Cold-section temperatures were not reproduced (bias up to −5.4 K), indicating an unmeasured disturbance and the need for inter-section measurements.

Förderung

  • Tashkent State Technical University of Uzbekistan

Zitieren

APA

Abdusalomov, A., Igamberdiyev, H., Amirov, S., Mamirov, U., Sevinov, J., Mukhiddinov, M., Umirzakova, S., & Whangbo, T. K. (2026). Physico-Analytical Modeling of an Industrial Low-Temperature Natural Gas Separation Line with Three-Section Cold Recovery and Propane Cooling. Processes, 14(22), 3645. https://doi.org/10.3390/pr14223645

Vancouver

Abdusalomov A, Igamberdiyev H, Amirov S, Mamirov U, Sevinov J, Mukhiddinov M, et al. Physico-Analytical Modeling of an Industrial Low-Temperature Natural Gas Separation Line with Three-Section Cold Recovery and Propane Cooling. Processes. 2026;14(22):3645. doi:10.3390/pr14223645

BibTeX
@article{Abdusalomov2026,
  author = {Abdusalomov, Akmalbek and Igamberdiyev, Husan and Amirov, Shaxzod and Mamirov, Uktam and Sevinov, Jasur and Mukhiddinov, Mukhriddin and Umirzakova, Sabina and Whangbo, Teag Keun},
  title = {Physico-Analytical Modeling of an Industrial Low-Temperature Natural Gas Separation Line with Three-Section Cold Recovery and Propane Cooling},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {22},
  pages = {3645},
  doi = {10.3390/pr14223645}
}
Kostenlos starten →