EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnosing Conformal Coverage Failure Under Battery Deployment Shift for Joint State-of-Charge and State-of-Health Estimation

Tao Zhang, Labani Akter, Xianyong Peng, Mohammad Raziul Hasan Rifat Sarkar

Processes · 04.11.2026 · 14 (21) · 3557

DOI: 10.3390/pr14213557 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 04.11.2026. Verfasst von Tao Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conformal prediction guarantees interval coverage only when calibration and deployment data are exchangeable. We test joint state-of-charge (SOC) and state-of-health (SOH) intervals when this assumption fails across cells, discharge protocols, chemistries, and an electric-vehicle (EV) driving profile, with calibration data kept separate from training and model selection. At 90% nominal, SOC coverage is 90.9% on a random cycle split but 33.0–81.4% on held-out cells, at most 0.9% on cross-protocol windows with nonzero SOC, at most 5.16% across chemistries, and 0.02% on EV-profile cells (five-seed means). SOH coverage is below nominal under every shift. Four learned baselines (recurrent, convolutional, Transformer, and physics-informed) and an equivalent-circuit Kalman filter fall short on the hardest cells. Density-ratio and optimal-transport weighting, conformalised quantile regression, and group-conditional calibration reach nominal mean coverage on no held-out cell. Recalibrating on the deployed cell’s five latest labelled cycles restores coverage to 85.5–90.3% on held-out cells without retraining, but under protocol and EV-profile shift only with intervals over half the SOC range. Under chemistry shift, optimal-transport alignment configured on labelled target data lowers SOC error by 10–59%, yet only fine-tuning with target-domain calibration restores coverage (88.0–89.3%). Source-calibrated conformal intervals are not valid under deployment shift by default.

Zitieren

APA

Zhang, T., Akter, L., Peng, X., & Sarkar, M. R. H. R. (2026). Diagnosing Conformal Coverage Failure Under Battery Deployment Shift for Joint State-of-Charge and State-of-Health Estimation. Processes, 14(21), 3557. https://doi.org/10.3390/pr14213557

Vancouver

Zhang T, Akter L, Peng X, Sarkar MRHR. Diagnosing Conformal Coverage Failure Under Battery Deployment Shift for Joint State-of-Charge and State-of-Health Estimation. Processes. 2026;14(21):3557. doi:10.3390/pr14213557

BibTeX
@article{Zhang2026,
  author = {Zhang, Tao and Akter, Labani and Peng, Xianyong and Sarkar, Mohammad Raziul Hasan Rifat},
  title = {Diagnosing Conformal Coverage Failure Under Battery Deployment Shift for Joint State-of-Charge and State-of-Health Estimation},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {21},
  pages = {3557},
  doi = {10.3390/pr14213557}
}
Kostenlos starten →