EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental and Numerical Investigation of Heat Transfer and Fluid Flow in Triply Periodic Minimal Surface Structures: Influence of Base Integration

Esa Dube Kerme, Mohammed Yahya, M. Ziad Saghir

Processes · 21.08.2026 · 14 (16) · 2672

DOI: 10.3390/pr14162672 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 21.08.2026. Verfasst von Esa Dube Kerme und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Research Council of Canada.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the heat transfer and fluid flow characteristics of six triply periodic minimal surface (TPMS) structures, specifically Gyroid (G3P6, G3P7, G3P8, G1P7) and Diamond (D1P7 and D3P7) configurations, using both experimental and numerical methods. Comparative analysis was conducted to evaluate the impact of adding a base to these structures on their thermal and hydraulic performance. The TPMS structures were assessed in terms of measured surface temperature, convection heat transfer coefficient, Nusselt number, overall thermal resistance, pressure drop, friction factor, and overall thermal–hydraulic performance. Results indicate that base-free structures exhibit better heat dissipation, with surface temperatures increasing by 1.2 °C (G3P6) to 5.5 °C (D3P7) when the base is added. The addition of the base reduces the convection heat transfer coefficient on average by 3.9% (G3P6) to 23% (D1P7) and increases overall thermal resistance by 3.1% (G3P6) to 28.7% (D1P7). The friction factor also rises by 6.1% (D1P7) to 47.3% (G3P6) due to the addition of the base. When the base is added, the overall thermal–hydraulic performance declines by 8.5% (G3P7) to 33.6% (D3P7), with Diamond structures experiencing a more significant reduction compared to Gyroid structures. Among the Gyroid structures, G3P6 (lower cell size and 60% porosity) demonstrated the lowest surface temperature and the highest heat dissipation capacity, while G3P8 (80% porosity) exhibited the lowest thermal performance. The Gyroid structure with larger cell size (G1P7) achieved the highest overall thermal–hydraulic performance, effectively balancing heat dissipation and fluid resistance. In contrast, when the base is integrated, the Gyroid structure with a smaller cell size and lower porosity (G3P6) showed the lowest overall thermal–hydraulic performance.

Förderung

  • Natural Research Council of Canada

Zitieren

APA

Kerme, E. D., Yahya, M., & Saghir, M. Z. (2026). Experimental and Numerical Investigation of Heat Transfer and Fluid Flow in Triply Periodic Minimal Surface Structures: Influence of Base Integration. Processes, 14(16), 2672. https://doi.org/10.3390/pr14162672

Vancouver

Kerme ED, Yahya M, Saghir MZ. Experimental and Numerical Investigation of Heat Transfer and Fluid Flow in Triply Periodic Minimal Surface Structures: Influence of Base Integration. Processes. 2026;14(16):2672. doi:10.3390/pr14162672

BibTeX
@article{Kerme2026,
  author = {Kerme, Esa Dube and Yahya, Mohammed and Saghir, M. Ziad},
  title = {Experimental and Numerical Investigation of Heat Transfer and Fluid Flow in Triply Periodic Minimal Surface Structures: Influence of Base Integration},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {16},
  pages = {2672},
  doi = {10.3390/pr14162672}
}
Kostenlos starten →