Fachartikel in der Zeitschrift Processes, online erschienen am 19.08.2026. Verfasst von Xingyang Fu und 2 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tianshan Talent Training Program of Xinjiang-Science and Technology Innovation Team, Xinjiang Major Science and Technology Special Project.
Abstract (Originalsprache)
In the context of the new power system, coal-fired units are transitioning into peaking units. This study investigates the combustion characteristics and NOX emissions of a 600 MW opposed wall-fired boiler within a load range of 50% to 20%, and further analyzes the impact of burner operation modes on boiler performance at the 20% ultra-low load. The results indicate that as the boiler load decreases from 50% to 20%, the average temperature in the primary combustion zone drops from 1634.3 K to 1457.0 K, and the ignition distance extends from 0.228 m to 0.260 m, leading to a significant decline in combustion stability. Notably, at the 20% ultra-low load, although the drop in temperature suppresses the formation of thermal NOX, the flow short-circuiting caused by the shrinking of the recirculation zone results in pulverized coal particles missing the optimal reduction window; the formation pathway dominated by fuel NOX causes the NOX concentration at the furnace outlet to surge to 670.6 mg/m3. Furthermore, the burner operation modes significantly influence boiler performance at the 20% ultra-low load. While ensuring combustion stability, operating the lower-tier burners effectively reduces NOX emissions by up to 21.6%. Considering both combustion stability and NOX emissions, prioritizing the operation of lower-tier burners is recommended. This study reveals the underlying mechanisms behind the surge in NOX concentrations at ultra-low loads of 20% and proposes optimal burner operation strategies, providing a theoretical foundation for the clean and stable operation of boilers during deep peak shaving.
Förderung
- Tianshan Talent Training Program of Xinjiang-Science and Technology Innovation Team
- Xinjiang Major Science and Technology Special Project
Zitieren
APA
Fu, X., Lu, H., & Zhao, W. (2026). Study on Combustion Characteristics and NOX Emissions of a 600 MW Opposed Wall-Fired Boiler Under Deep Peak Shaving. Processes, 14(16), 2645. https://doi.org/10.3390/pr14162645
Vancouver
Fu X, Lu H, Zhao W. Study on Combustion Characteristics and NOX Emissions of a 600 MW Opposed Wall-Fired Boiler Under Deep Peak Shaving. Processes. 2026;14(16):2645. doi:10.3390/pr14162645
BibTeX
@article{Fu2026,
author = {Fu, Xingyang and Lu, Hao and Zhao, Wenjun},
title = {Study on Combustion Characteristics and NOX Emissions of a 600 MW Opposed Wall-Fired Boiler Under Deep Peak Shaving},
journal = {Processes},
year = {2026},
volume = {14},
number = {16},
pages = {2645},
doi = {10.3390/pr14162645}
}
EUVIMED